POTENZE IMPEGNATE PER I VENTILATORI TRIFASE MONTATI SUI CONDENSATORI SHV 800 - SHVD O RAFFREDDATORI DI LIQUIDO SHL 800 - SHLD
POWER DRAWN BY THREE PHASE VENTILATOR MOTORS INSTALLED ON SHV 800 - SHVD CONDENSERS OR SHL 800 - SHLD DRY COOLERS
PUISSANCES UTILISEES PAR LES VENTILATEURS TRIPHASES MONTES SUR LES CONDESEURS SHV 800 - SHVD OU LES AEROREFRIGERANTS SHL 800 - SHLD
STROMAUFNAHME FÜR DIE IN DEM VERFLÜSSIGERN SHV 800 - SHVD BZW. FLÜSSIGKEITSRÜCKKÜHLERN SHL 800 - SHLD EINGEBAUTEN DREHSTROMVENTILATOREN
Ventilatori / Fans / Ventilateurs / Ventilatoren
Mod. ventilatori / Fans type / Mod. ventilateurs
Mod. Ventilatoren / Mod. ventiladores
(A)
1x1
1
1
3,95
1x2
1
2
7,9
1x3
1
3
11,85
1x4
1
4
15,8
1x5
1
5
19,75
1x6
1
6
23,7
1x7
1
7
27,65
2x2
2
2
15,8
2x3
2
3
23,7
2x4
2
4
31,6
2x5
2
5
39,5
2x6
2
6
47,4
2x7
2+1
8
55,3
2x8
2
8
63,2
2x9
2
9
71,1
2x10
2
10
79
2x11
2
11
86,9
Mod. ventilatori / Fans type / Mod. ventilateurs
Mod. Ventilatoren / Mod. ventiladores
(A)
1x1
1
1
2,45
1x2
1
2
4,9
1x3
1
3
7,35
1x4
1
4
9,8
1x5
1
5
12,25
1x6
1
6
14,7
1x7
1
7
17,15
2x2
2
2
9,8
2x3
2
3
14,7
2x4
2
4
19,6
2x5
2
5
24,5
2x6
2
6
29,4
2x7
2
7
34,3
2x8
2
8
39,2
2x9
3
6
44,1
2x10
3+2
7
49
2x11
3+2
8
53,9
Mod. ventilatori / Fans type / Mod. ventilateurs
Mod. Ventilatoren / Mod. ventiladores
(A)
1x1
1
1
1,95
1x2
1
2
3,9
1x3
1
3
5,85
1x4
1
4
7,8
1x5
1
5
9,75
1x6
1
6
11,7
1x7
1
7
13,65
2x2
2
2
7,8
2x3
2
3
11,7
2x4
2
4
15,6
2x5
2
5
19,5
2x6
2
6
23,4
2x7
2
7
27,3
2x8
2
8
31,2
2x9
3
6
35,1
2x10
3+2
7
39,0
2x11
3+2
8
42,9
FE 800
QE...
FU1 FU2 FU3
FU1
1/20A
1
-
-
2/20A
2
-
-
3/20A
3
-
-
4/20A
4
-
-
5/20A
5
-
-
6/32A
3
3
-
7/32A
4
3
-
2/20A
4
-
-
3/32A
4
2
-
4/32A
4
4
-
5/60A
4
4
2
6/60A
4
4
4
8/60A
5
5
4
2x 4/32A
2x 4 2x 4
-
2x 20
4/32A + 5/60A
4+4 4+4 0+2 20+20 20+20 0+10
2x 5/60A
2x 4 2x 4 2x 2
2x 20
5/60A + 6/60A
4+4 4+4 2+4 20+20 20+20 10+20
FE 800
QE...
FU1 FU2 FU3
1/20A
1
-
-
2/20A
2
-
-
3/20A
3
-
-
4/20A
4
-
-
5/20A
5
-
-
6/32A
6
-
-
7/32A
7
-
-
2/20A
4
-
-
3/20A
6
-
-
4/20A
8
-
-
5/32A
6
4
-
6/32A
6
6
-
7/60A
6
4
4
8/60A
6
6
4
6/60A
6
6
6
7/60A
8
6
6
8/60A
8
8
6
FE 800
QE...
FU1 FU2 FU3
FU1
1/20A
1
-
-
2/20A
2
-
-
3/20A
3
-
-
4/20A
4
-
-
5/20A
5
-
-
6/20A
6
-
-
7/20A
7
-
-
2/20A
4
-
-
3/20A
6
-
-
4/20A
8
-
-
5/20A
10
-
-
6/32A
6
6
-
7/32A
8
6
-
8/32A
8
8
-
6/60A
6
6
6
7/60A
8
6
6
8/60A
8
8
6
Ø 800 mm
(A)
6P
FU2
FU3
R2PR-R2TE-RS
6
-
-
12A
10
-
-
12A
16
-
-
12A
20
-
-
20A
25
-
-
20A
16
16
-
25A
20
16
-
40A
20
-
-
20A
20
10
-
25A
20
20
-
40A
20
20
10
40A
20
20
20
60A
25
25
20
60A
2x 20
-
2x 40A
2x 40A
2x 20 2x 10
2x 40A
40A+60A
8P
FU1
FU2
FU3
R2PR-R2TE-RS
4
-
-
12A
6
-
-
12A
10
-
-
12A
12
-
-
12A
16
-
-
12A
20
-
-
20A
25
-
-
20A
12
-
-
12A
20
-
-
20A
25
-
-
20A
20
12
-
25A
20
20
-
40A
20
12
12
40A
20
20
12
40A
20
20
20
60A
25
20
20
60A
25
25
20
60A
8PS
FU2
FU3
R2PR-R2TE-RS
4
-
-
12A
6
-
-
12A
8
-
-
12A
10
-
-
12A
12
-
-
12A
16
-
-
12A
20
-
-
20A
10
-
-
12A
16
-
-
12A
20
-
-
20A
25
-
-
20A
16
16
-
25A
20
16
-
40A
20
20
-
40A
16
16
16
40A
20
16
16
40A
20
20
16
60A
7
REGOLATORE / SPEED REGULATOR
REGULATEUR / REGLER
R2PR - R2TE - RS
Quando è indicata la quantità dei
ventilatori con 2xn ventilatori, su ogni
1
contattore sono collegati 2 ventilatori
in parallelo.
1
1
When the fan number is indicated as
1
2xn fans, two parallel fans are wired
on each contactor.
1
1
Lorsqu'il est indiqué un nombre de
1
ventilateurs 2xn, chaque contacteur
contrôle deux ventilateurs en
2
parallèle.
2
2
Wenn bei der Ventilatoranzahl 2xn
Ventilatoren angegeben sind, sind
2
swei Ventilatoren parallel auf elnen
2
Schütz verdrahtet.
2
2
2
Tk
Ma
Tk
~
2
2
1
1
Alla rete / To mains
1
Auréseau / Zum Netz
1
1
1
1
2
2
2
2
2
2
2
2/3
2/3
2/3
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2/3
2/3
2/3
Mb
~
Tk