POTENZE IMPEGNATE PER I VENTILATORI TRIFASE MONTATI SUI CONDENSATORI SHV 800 - SHVD O RAFFREDDATORI DI LIQUIDO SHL 800 - SHLD
POWER DRAWN BY THREE PHASE VENTILATOR MOTORS INSTALLED ON SHV 800 - SHVD CONDENSERS OR SHL 800 - SHLD DRY COOLERS
PUISSANCES UTILISEES PAR LES VENTILATEURS TRIPHASES MONTES SUR LES CONDESEURS SHV 800 - SHVD OU LES AEROREFRIGERANTS SHL 800 - SHLD
STROMAUFNAHME FÜR DIE IN DEM VERFLÜSSIGERN SHV 800 - SHVD BZW. FLÜSSIGKEITSRÜCKKÜHLERN SHL 800 - SHLD EINGEBAUTEN DREHSTROMVENTILATOREN
Ventilatori / Fans / Ventilateurs / Ventilatoren
Mod. ventilatori / Fans type / Mod. ventilateurs
Mod. Ventilatoren / Mod. ventiladores
(A)
1x1
1
1
1
1x2
1
2
2
1x3
1
3
3
1x4
1
4
4
1x5
1
5
5
1x6
1
6
6
1x7
1
7
7
2x2
2
2
4
2x3
2
3
6
2x4
2
4
8
2x5
2
5
10
2x6
2
6
12
2x7
2
7
14
2x8
2
8
16
2x9
3
6
18
2x10
3+2
7
20
2x11
3+2
8
22
Mod. ventilatori / Fans type / Mod. ventilateurs
Mod. Ventilatoren / Mod. ventiladores
(A)
1x1
1
1
0,62
1x2
1
2
1,24
1x3
1
3
1,86
1x4
1
4
2,48
1x5
1
5
3,1
1x6
1
6
3,72
1x7
1
7
4,34
2x2
2
2
1,24
2x3
2
3
3,72
2x4
2
4
4,96
2x5
2
5
6,2
2x6
2
6
7,44
FE 800
QE...
FU1 FU2 FU3
FU1
1/20A
1
-
-
2
2/20A
2
-
-
4
3/20A
3
-
-
4
4/20A
4
-
-
6
5/20A
5
-
-
6
6/20A
6
-
-
8
7/20A
7
-
-
10
2/20A
4
-
-
6
3/20A
6
-
-
8
4/20A
8
-
-
10
5/20A
10
-
-
12
6/20A
12
-
-
16
7/20A
14
-
-
20
8/20A
16
-
-
20
6/20A
18
-
-
25
7/20A
20
-
-
25
8/32A
11
11
-
16
FE 800
QE...
FU1 FU2 FU3
FU1
1/20A
1
-
-
1
2/20A
2
-
-
4
3/20A
3
-
-
4
4/20A
4
-
-
4
5/20A
5
-
-
4
6/20A
6
-
-
6
7/20A
7
-
-
6
2/20A
4
-
-
4
3/20A
6
-
-
6
4/20A
8
-
-
8
5/20A
10
-
-
8
6/20A
12
-
-
16
Ø 800 mm
(A)
12P
FU2
FU3
R2PR-R2TE-RS
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
20A
-
-
20A
-
-
20A
-
-
20A
16
-
25A
12PS
FU2
FU3
R2PR-R2TE-RS
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
8
REGOLATORE / SPEED REGULATOR
REGULATEUR / REGLER
R2PR - R2TE - RS
Quando è indicata la quantità dei
ventilatori con 2xn ventilatori, su
ogni contattore sono collegati 2
1
ventilatori in parallelo.
1
1
When the fan number is indicated
as 2xn fans, two parallel fans are
1
wired on each contactor.
1
1
Lorsqu'il est indiqué un nombre de
1
ventilateurs 2xn, chaque
2
contacteur contrôle deux
ventilateurs en parallèle.
2
2
Wenn bei der Ventilatoranzahl 2xn
2
Ventilatoren angegeben sind, sind
2
swei Ventilatoren parallel auf elnen
2
Schütz verdrahtet.
2
2/3
2/3
2/3
Tk
~
Ma
Tk
1
1
1
1
Alla rete / To mains
Auréseau / Zum Netz
1
1
1
2
2
2
2
2
~
Mb
Tk