Generator Maintenance

The generator's warranty does not cover items that
have been subjected to operator abuse or negligence.
To receive full value from the warranty, the operator
must maintain the generator as instructed in this
manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All service and adjustments should be made at least
once each season. Follow the requirements in the
Maintenance Schedule chart.
Generator maintenance consists of keeping the unit
clean. Operate the unit in an environment where it will
not be exposed to excessive dust, dirt, moisture or any
corrosive vapors. Cooling air louvers on the enclosure
must not become clogged with snow, leaves, or any
other foreign material. To prevent generator damage
caused by overheating, keep the enclosure cooling
inlets and outlets clean and unobstructed at all times.
Check the cleanliness of the unit frequently and
clean when dust, dirt, oil, moisture or other foreign
substances are visible on its exterior/interior surface.
Inspect the air inlet and outlet openings inside and
outside the enclosure to ensure air flow is not blocked.
DO NOT use direct spray from a garden hose to clean
generator. Water can enter the engine and generator
and cause problems.
NOTICE Improper treatment of generator could
damage it and shorten its life.
• DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
• DO NOT insert any objects through cooling slots.
Clean the generator as follows:
1. Press and hold the control board OFF button.
2. Remove 15 Amp fuse from control board.
3. Clean generator as desired.
• Use a damp cloth to wipe exterior surfaces clean.
• Use a soft, bristle brush to loosen caked on dirt,
etc.
• Use a vacuum cleaner to pick up loose dirt and
debris.
• Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and openings
on the generator. These openings must be kept
clean and unobstructed.
4. Reinstall 15 Amp fuse in control board.
5. Press and hold the control board AUTO button.
44
Battery
WARNING Battery posts, terminals and related
accessories contain lead and lead compounds, chemicals
known to the State of California to cause cancer and
reproductive harm. Wash hands after handling.
Servicing of batteries is to be performed or supervised
by personnel knowledgeable of batteries and the
required precautions. Keep unauthorized personnel
away from batteries.
Servicing the Battery
If it is necessary to service the battery, proceed as follows:
1. Press and hold the control board OFF button.
2. Remove 15 Amp fuse from control panel.
3. Service or replace battery as required. See
Battery in Final Installation Considerations in the
installation manual for specific battery needed.
4. Connect red battery cable to battery positive
terminal (indicated by POSITIVE, POS, or (+)).
6. Connect black negative battery cable to negative
battery terminal (indicated by NEGATIVE, NEG, or (-).
7. Ensure hardware on both positive and negative
battery terminals is secure.
8. Reinstall 15 Amp fuse in control panel.
9. Press and hold the control board AUTO button.
DON'T POLLUTE. CONSERVE RESOURCES,
RETURN USED BATTERY TO RECYCLING
COLLECTION CENTER.

Charging the Battery

If it is necessary to charge the battery, proceed as follows:
1. Press and hold the control board OFF button.
2. Remove 15 Amp fuse from control board.
3. Disconnect negative battery cable from negative battery
terminal (indicated by NEGATIVE, NEG, or (-)).
4. Charge battery with battery charger at 2 Amps
until battery holds 12 Volts. DO NOT exceed
13.7 volts when charging.
NOTICE Failure to disconnect negative battery cable
could result in equipment failure.
• DO NOT attempt to jump start the generator.
• Damage to equipment resulting from failure to follow this
instruction will void engine and generator warranty.
NOTICE DO NOT use a battery booster to quick
charge a low battery.
5. Connect negative battery cable to negative battery
terminal (indicated by NEGATIVE, NEG, or (-)).
6. Ensure hardware on both positive and negative
battery terminals is secure.
7. Reinstall 15 Amp fuse in control board.
8. Press and hold the control board AUTO button.