7. Malfunction table
At a possible malfunction one can consult the table mentioned below and if you obtain on this basis no solution, we
advise to contact a DiBO- technician and/or a recognized DiBO- representative.
Malfunction
Machine does not start
No water pressure
Instable and to weak pressure
No hot water
Aerator does not turn
HP pump pulse
Hot water temperature is not
reached
Closing mechanism fault of cap
Insufficient braking of trailer
Overheating of the brakes of
trailer
Cause
Battery insufficient
No fuel in engine
Key switch off
Rest malfunctions
Few water supply
Filter blocked
Air in water supply (leaks in water
supply)
Nozzle or lance blocked or worn-out. Clean or replace
Pressure regulator defect
Rest malfunctions
Burner switch not on position "1"
No fuel present in the tank
Temperature sensor defective
Rest of malfunctions
Fuse defect
Burner switch not on position "1"
Electrical motor defective
Leak or congestion in supply conduit Clean/replace/repair
To much air present
Temperature too low or working
pressure to high
Key contact and/or closing mecha-
nism defective
Excessive friction losses or corrosion
on the drawbar
Damage caused by impact during
manoeuvring
Hand brake not released
Jockey wheel blocking linkage
DiBO n.v. 89
Solution
Recharge and/or replace battery
Fill the tank with fuel
Put key switch on
Consult an expert
Repair water supply
Clean/replace filter cartridge
Put machine completely without power!
Repair leaks in supply.
Consult an expert
Consult an expert
Put switch on position "1"
Fill the tank, clean or replace the fuel filter
Consult an expert
Consult an expert
Check fuse
Put burner switch on position "1"
Consult an expert
De aeration of cleaner
Higher temperature control + reduce work
pressure
Push left and right locking pin to open
Remove dirt/corrosion from transmission
system + remove brake and then check
that the system operates smoothly
Consult an expert
Release hand brake
Release jockey wheel and move into the
correct position