Burner; General Control Of The Tanks; Malfunction Table - Dibo IBH Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

E N
    M A L F U N C T I O N TA B L E
STORING
Machine does not start
No water pressure
Instable and to weak pressure
Water in product tank
No additions of products
No hot water
Aerator does not turn
HP pump pulse
Hot water temperature is not reached
7

Burner

Check if the burner opening is clear of pollution. Check pipes and connections
on leaks and external damages. Replace the filter if necessary.
Ignition transformer from the burner:
It is important that on the ignition transformer a load is connected. The
switching on of the ignition transformer without the ignition pins are connected,
are not permitted. We recommend during maintenance activities certainly
checking the connections of the ignition cables and for the case the burner
would not work, certainly don't run the burner.
8

General control of the tanks

Check all tanks on external damages and leaks.
Check at filling of the water tank if the float system works properly.

Malfunction table

At a possible malfunction one can consult the table mentioned below and if you
obtain on this basis no solution, we advise to contact a DiBO- technician and/or
a recognized DiBO- representative.
OORZAAK
• Electrical supply not connected
• Net fuse defect
• Main switch on "0"
• Rest malfunctions
• Few water supply
• Filter blocked
• Air in water supply (leaks in water
supply)
• Nozzle or lance blocked or worn-
out.
• Pressure regulator defect
• Rest malfunctions
• Non return valve in filter defect
• Suction pipe
• Suction filter stuffed-up
• Product tank empty
• Spray pressure to high
• Burner switch not on position "1" or
warm water button not switched
on.
• No fuel present in the tank
• Temperature sensor defective
• Rest of malfunctions
• Net fuse defect
• Burner switch not on position "1" or
warm water button not switched
on.
• Electrical motor defective
• Leak or congestion in supply
conduit
• To much air present
• Temperature too low or working
pressure to high
DiBO 26
OPLOSSING
• Connect the electrical supply
• Check net fuse
• Put main switch on "1"
• Consult an expert
• Repair water supply
• Clean/replace filter cartridge
• Put machine completely without
power! Repair leaks in supply.
• Clean or replace
• Consult an expert
• Consult an expert
• Replace suction filter
• Repair suction pipe
• Clean suction filter
• Refill or replace tank
• Lower spray pressure
• Put main switch on position "1" or
check display if the warm water
button is pushed.
• Fill the tank, clean or replace the
fuel filter
• Consult an expert
• Consult an expert
• Check net fuse
• Put burner switch on position "1"
or check display if the warm water
button is pushed.
• Consult an expert
• Clean/replace/repair
• De-aeration of cleaner
• Higher temperature control +
• reduce work pressure

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1.780.020

Table des Matières