Shut-Down Instructions - L.B. White Premier TS040 Manuel Du Propriétaire Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

16
Premier Ductable Heater

Shut-Down Instructions

For normal shut-down, set the thermostat below room
temperature. When servicing or performing maintenance,
follow steps 1 - 5.
1. Close the fuel supply valve.
2. Allow the heater to burn off any fuel gas remaining in the
gas supply line.
4. Position selector switch to O (off).
5. Disconnect the heater from its gas and electrical sup-
plies.
Gas Selector Valve Dual
Fuel (DF) Models
This heater is shipped from the factory with the fuel selector
valve in the propane gas (LP) position. Ensure the fuel
selector valve's handle is properly positioned for the fuel
being used.
1. This feature allows the heater to operated on either
propane or natural gas without changing out the burner
control valve and the burner. THIS IS NOT A MANUAL
GAS SHUT OFF VALVE.
2. Refer to Figs. 14 and 15 for valve handle proper posi-
shown. Same handle positions for Premier 80 DF).
proper operation. Also refer to the decal located on the
heater's base, adjacent to the selector valve.
Owner's Manual • Premier Ductable Heater
FIG. 14
FIG. 15
DO NOT operate the heater with selector valve handle
set between either position, otherwise improper
operation will occur.