AC PILOT LIGHT/OVERLOAD WARNING LIGHT
A
1
B
1
A
B
AC PILOT LIGHT
Checking steps:
å For Canada and Australia
∫ For Europe and Korea
OVERLOAD WARNING LIGHT
The overload warning light 1 comes on when
an overload of a connected electrical device is
1
detected, the inverter control unit overheats, or
the AC output voltage rises. Then, the AC pro-
tector will trip, stopping power generation in
order to protect the generator and any con-
nected electric devices. The AC pilot light
(green) will go off and the overload warning
light (red) will stay on, but the engine will not
stop running.
When the overload warning light comes on
1
and power generation stops, proceed as fol-
lows:
å For Canada and Australia
∫ For Europe and Korea
2-24
1. Check:
9 AC pilot light 1
9 Start the engine.
9 Check that the AC pilot light 1 turns
on.
Refer to "GENERATOR SYSTEM" in
CHAPTER 5.
1. Turn off any connected electric devices
and stop the engine.
2. Reduce the total wattage of connected
electric devices within the rated output.
INSP