Robert Juliat D'ARTAGNAN 930 SNX Dossier Technique page 29

Masquer les pouces Voir aussi pour D'ARTAGNAN 930 SNX:
Table des Matières

Publicité

3.3. The o command is given, but the lamp
stays on.
Green &
red LED :
o
Green &
red LED
on.
4 . NON-FUNCTIONING DIAGNOSIS FOR THE SHUTTER :
1.1 The shutter command is given, but no
action.
1.2 . The shutter only excepts an up command,
does not accept a down command.
1.3 . The shutter reacts badly, and the motor
runs continuously.
1.4. The shutter act in a saw-tooth movement
on a uent command.
1.5. Shutter action is delayed to command.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
DOSSIER TECHNIQUE
DECOUPES MSR 2500W
message unchanged.
message unchanged.
New shutter level
not displayed.
New shutter level
displayed.
The shutter does
not react or reacts
badly.
The shutter level is
correctly displayed.
Transmission Data error :
connection failure : check the wiring.
( refer to sections A - 7 & A - 14 ).
connection damaged or disturbed :
( refer to sections A - 7 & A - 14 ).
Command link error :
Digital - refer to 3.1.
Analog - refer to 2.
Shutter cable damaged :
Check cable.
Faulty power supply :
Change CAD :
( Refer to section C - 10 )
Motor damaged : Change the
whole shutter unit.
( refer to section C - 7 )
Error on the shutter unit :
Change the whole shutter unit.
( refer to section C - 7 )
900 SNX
Section B - 11
Resend the
"LAMP OFF"
command.
Resend the
"LAMP OFF"
command.
resend the
resend the
level
level
command.
command.
resend the
level
command.
resend the
level
command.
resend the
level
command.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

D'artagnan 933 snxD'artagnan 934 snx

Table des Matières