CONNECTIONS.

Mains voltage.
- Check the conformity of the mains voltage input with
the values indicated on the identification plate of the
PSU (mains voltage & lamp power)
Rating plate 7 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lamp cable C to the connector 5 of the
ballast and connector e to the lighting unit.
- Connect the cable D to the connector ( d ) of the
ballast and to the connector f of the lighting unit "XLR7".
- Place the lamp into position - refer to section A - 7.
- Connect the DATA line on connector ( a ) "XLR5" or
the analog command to the connector ( c ) "XLR4".
( For the connection configurations : refer to section B - 3 ).
- Connect the optional units that are possible, to connector g
( Only DATA ).
- Plug the cable 6 to the mains. If the power is present, the
checklight 1 lights up immediately.
- Engage the circuit breaker 3 and check that the CAD 900
protection 4 is well engaged.
- If you use the optional outlet h , engage the circuit breaker 2 .
WARNING !
- Never open the lamp house's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp in place.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
2500W MSR PROFILES
A
h
e
f
g
C
Each time you switch on: make sure
the fans are working correctly.
B
5
3 4
1 2
7
6
DATA in.
• Use only the listed cables to connect to the mains -
Refer to the respective PSU technical file.
DESCRIPTION.
A 900 SNX Motorized shutter - CAD 900 version.
e - EM HARTING 16 x 16A power socket.
f - EM XLR7 shutter + DATA (option).
g - EF XLR5 output DATA (colour changer option).
h - EF mains output 220/240V (colour changer option).
B Power supply unit with CAD 900 control module.
a - EM XLR5 input DATA.
0/10V - DMX 512 - AVAB
b - EF XLR5 output DATA.
ERROR
c
SELECT
EXIT
+
a
DATA
c - EM XLR4 0/+10V input.
EXT. DIGI.
LOCK
EXT.
LOCAL
RESET
d
b
d - EF XLR7 output DATA luminaire.
DATA
0/10V
CONTROL
SHUTTER
C Lamp cable.
Cable H07 RN-F 18G 1,5 mm
with 16 x 16A M/F HARTING connectors.
D Shutter cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR7 M/F connector.
900 SNX
Section A - 5
OPTION
DMX colour
changer.
D
0/+10V. line.
DATA out.
2
length 3m fitted