MAINTENANCE
REFLECTOR.
- Disconnect from the mains.
- Open the bonnet of the lamp house.
- Take out the lamp.
(Refer to section A - 7).
- Clean the reflector 1 with a soft dry cloth.
ASPHERIC LENS.
- Unscrew the lock 2 .
- Take out the lens holder set 3 .
- Clean the lens with a soft dry cloth.
- Remount the lens holder set.
- Clean in the same way, the lenses in the lens tube.
Check the lamp position.
SPARK-GAP.
- Disconnect from the mains.
- Open the lamp house bonnet.
- Check the distance of the electrodes that should be 1mm.
(If you notice a larger gap, then please contact the ROBERT JULIAT's
technical department).
service@robertjuliat.fr
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
DOSSIER TECHNIQUE
DECOUPES MSR 2500W
Disconnect from the mains before any servicing.
Service only by qualified technician.
MINI = 7mm.
900 SNX
2
3
1 mm