Technical Characteristics; Admissible Lamps - Robert Juliat D'ARTAGNAN 930 SNX Dossier Technique

Masquer les pouces Voir aussi pour D'ARTAGNAN 930 SNX:
Table des Matières

Publicité

Manufacturer's recommendations :
• Read attentively the manufacturer's instructions.
• Positioning of the lamp and connecting the power supply require great care. To make sure there is a good
conduction of current, the mechanical support and the electrical connections must be free from dirt and corrosion.
The clamps and brackets must be checked whenever the lighting unit has been transported.
• The lamp emits ultraviolet radiation. Direct exposure can be harmful to your health.
• It is recommended to avoid air draughts, also avoid exposing the lighting unit to bad weather.
• Use only when bulb in place

Technical characteristics :

Voltage at the terminals of the lamp ................................................................................................................................. 115 Volts
Amperage at the terminals of the lamp .......................................................................................................................... 25,6 Amps
Luminosity of the lamp ...................................................................................................................................................... 240 000 lm
Luminous efficacy ....................................................................................................................................................................96 lm/W
Colour temperature ........................................................................................................................................................... 6000 Kelvin
Base ...................................................................................................................................................................................................... G38
Manufacturer's rated life ..................................................................................................................................................... 500 hours
User's precautions :
• The lamplife, as given by the manufacturer, is a theoretic lamplife duration as "in laboratory conditions",
a cycle based on 3 hours on / 1 hour off. Briefer cycles reduce the duration of the lamplife.
• In operating conditions, it is uncommon, for the lamp to still be fully efficient after 200 to 300 hours.
Its efficiency can decrease by 30%.
• Premature wearing of lamp under performing conditions is mainly due to frequent switching on. Better leave
the lamp on, through the performance, rather than switching it on repeatedly. ( The lamplife is reduced about
1 hour, each time the lamp is switched on ). It is advised to wait for 10 minutes before switching on again.
(This extends the duration of the lamp.)
• Use over 500 hours of the lamp : change the lamp even if it still lights up.
New lamp :
• To achieve a good ionization of a new lamp, when using it for the first time, it is recommended to leave it on
for a few hours.
• Preserve carefully the guarantee slip of the lamp, as it may be asked for in the event to resolve a dispute.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
2500W MSR PROFILES
ADMISSIBLE LAMP :
PHILIPS: MSR 2500 HR
900 SNX
Section A - 9
Thank you.