CAD 900/Mechanical Shutter cable
d
CAD 900 side
FM XLR 7
DESIGNATION
REP
1
0V
2
DATA -
3
DATA +
4
PWM
5
INFO 0/+10V
6
+U
7
- U
/
SHELL
g
Ballast side
FMD 16 x16 A
Harting
DESIGNATION
REP
1
Fan phase
2
Ballast phase
3
Lamp Neutral
4
5
6
Security return 1200W
7
Security return 2500W
8
Security not used
Note: This is a universal cable and is suitable for a 1200W / 2500W
followspot or pro le.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
DOSSIER TECHNIQUE
g
Flexible cable
5 x 0,14 shielded
CN5
DESIGNATION
REP
1
0V
2
DATA - IN
3
DATA + IN
4
5
Delivered standard : 3m
Flexible cable
14 x 0,14 shielded
CN14
4 x 0,14
1 x 0,14
1 x 0,14
1 x 0,14
1 x 0,14
3 x 0,14
3 x 0,14
Shielded
Lamp cable
Delivered standard : 3m
Cable H07 RN-F
18G 1,5mm
2
DESIGNATION
REP
9
Ignition timed phase
10
Ballast phase
11
Lamp Neutral
12
Earth
13
Aux. phase
14
Aux. Neutral
15
Common security
16
Earth
Female side earth only
DECOUPES MSR 2500W

CONNECTION.

DATA Link
a
b & f
FF XLR 5
FM XLR 5
5 x 0,14 shielded
DESIGNATION
REP
1
0V
2
DATA - OUT
3
DATA + OUT
4
5
e
Shutter side
FF XLR 7
DESIGNATION
REP
1
0V
2
DATA -
3
DATA +
4
PWM
5
INFO 0/+10V
6
+U
7
- U
NC
/
h
Lighting unit side
FFD 16 x16 A
Harting
900 SNX
Flexible cable
CN5
0/+10V control
Flexible cable
5 x 0,14 shielded
DESIGNATION
REP
1
0V GND
2
Lamp circuit
3
Shutter circuit
4
+15V
k
250V -10A IEC C14 male power connector,
for fan power feed.
REP
DESIGNATION
L
Phase
N
Neutral
Earth