11
Troubleshooting
11.1
General troubleshooting
Error symptom
No display after
power-up
Configuration error
following power-up
11.2
Fault inspection with regard to individual measurements
The supplements on the corresponding measuring modules contain detailed descriptions of
fault inspections.
417101163_Multronic.doc
Cause / Defect
Not connected to supply power
Defective mains fuse
Defective power supply unit
Flatplug connection loose
Contrast not set
Defective processor board
Existing module and confi-
guration are not compatible
- 79 -
Remedy
Connect to voltage
Replace fuse
Send unit to factory for repairs
Tighten connector
Set contrast using potentiometer on the
processor board
Send unit to factory for repairs
Check configuration and module
Re-configure unit
Rev: 5.07-08