Video encoder (Release B)
• Communication protocol: ONVIF, Profile S and
Profile Q
• Streaming: RTSP, RTCP, RTP/IPv4, Multicast
• Video compression: H.264/AVC, MJPEG, MPEG4,
JPEG
• Up to 3 simultaneous video streams
• Image resolution: from Full D1 (720x576 for PAL,
720x480 for NTSC) to 352x240
• Selectable frame rate from 1 to 60 images per
second (fps)
• Web Server

16.2.8 I/O interface

I/O alarm board
• Alarm inputs: 1
• Relay outputs: 1 (1A, 30Vac/60Vdc max)
Cable length: 200m (656ft) max

16.2.9 Cameras

Power consumption (assembly, camera and lens)
• Without video encoder IP: 8W
• With video encoder IP: 6W
Minimum distance between camera and housing's
window: 4mm (0.16in)
Cameras dimensions/Lenses that can be installed
(WxHxL)
• Without video encoder: 70x65x140mm
(2,6x2,5x5,5in)
• With video encoder: 70mmx65mmx120mm
36

16.2.10 Environment

For installation indoors and outdoors
Operating temperature:
• Cold start from -40°C (-40°F) up to +65°C (149°F)
• Running from -50°C (-58°F) up to +65°C (149°F)
Relative humidity: from 10% up to 95% (no
condensation)

16.2.11 Certifications

ATEX (EN 60079-0: 2012, EN 60079-1: 2014, EN 60079-
31: 2014)
b b II 2 G Ex db IIC T5 Gb
b b II 2 D Ex tb IIIC T100°C Db IP66/IP68
-60°C ≤ Ta ≤ +65°C
b b II 2 G Ex db IIC T5 Gb
b b II 2 D Ex tb IIIC T100°C Db IP66/IP68
-50°C ≤ Ta ≤ +65°C
b b II 2 G Ex db IIC T6 Gb
b b II 2 D Ex tb IIIC T85°C Db IP66/IP68
-60°C ≤ Ta ≤ +55°C
b b II 2 G Ex db IIC T6 Gb
b b II 2 D Ex tb IIIC T85°C Db IP66/IP68
-50°C ≤ Ta ≤ +55°C
IECEx (IEC 60079-0: 2011 Ed.6, IEC 60079-1: 2014-06
Ed.7, IEC 60079-31: 2013 Ed.2)
Ex db IIC T5 Gb
Ex tb IIIC T100°C Db IP66/IP68
-60°C ≤ Ta ≤ +65°C
Ex db IIC T5 Gb
Ex tb IIIC T100°C Db IP66/IP68
-50°C ≤ Ta ≤ +65°C
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db IP66/IP68
-60°C ≤ Ta ≤ +55°C
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db IP66/IP68
-50°C ≤ Ta ≤ +55°C
TYPE 6P, TYPE 4X (UL50E)
IP69 (EN/IEC60529), housing only
IP66/IP67/IP68 (2 hours, 5m (16ft), EN/IEC60529)