PRODUCT DIMENSIONS AND
CLEARANCES (Cont.)
Using Duct Cover Accessories
A Duct Cover Accessory may be required for your
hood installation height. Use this chart to determine
installation height and accessory for your ceiling
height.
ZV950SDSS Installation Heights
Actual Ceiling
Height
Installation Height
7' 11"
8' 0"
8' 1"
8' 2"
8' 3"
8' 4"
8' 5"
8' 6"
8' 7"
8' 8"
8' 9"
8' 10"
8' 11"
9' 0"
9' 1"
9' 2'
9' 3'
9' 4"
9' 5"
9' 6"
9' 7"
9' 8"
9' 9"
9' 10"
9' 11"
10' 0"
14' 0"
* Based on 36" countertop height.
The serial plate is located behind the removable filters.
4
Design Information
* Possible Hood
Duct
Cover
24-1/2"
25-1/2"
25-1/2" to 26-1/2"
25-1/2" to 27-1/2"
25-1/2" to 28-1/2"
25-1/2" to 29-1/2"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
26-1/2" to 30"
26-1/2" to 30"
26-1/2" to 30"
26-1/2" to 30"
26-1/2" to 30"
30" min.
30" min.
30" min.
30" min.
30" min.
30" min.
30" min.
OPTIONAL ACCESSORIES
Using Duct Cover Accessories
ZX14SDSS, optional stainless steel duct cover is
available for ceiling heights greater than 10 ft. and up
to 14 ft.
Order the optional duct cover at the same time as the
vent hood and have on site before installation. This
kit contains hardware required for installation. This kit
contains installation hardware.
NOTE: Duct covers must be installed as shown in
this book. Do not "build-in" the duct cover. If service is
required, the duct cover must be removed to access
hood components.
1" = 2.5 cm; 1' = 0.3 m
31-14900 Rev. 2