Install The Hood; Connect Ductwork - Monogram ZV950 Instructions D'installation

Hotte en acier inoxydable de 36 po
Masquer les pouces Voir aussi pour ZV950:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4 INSTALL THE HOOD

Place the hood on the brackets and slide left or right to
center.
1. A djust the installation levelness by tightening
or loosening the screws "A" at the bottom of the
brackets.
2. Mark the 2 lower mounting holes.
3. Remove the hood from the wall.
4. D rill a pilot hole in each lower mounting hole
location. The two lower holes can be enlarged to
3/8" if they did enter studs. Tap anchors for wall
fasteners into the bottom holes. Screws should be
inserted by hand into the fasteners to allow anchors
to expand against the wall material. Remove the
screws for final installation.
5. R eplace the hood on the mounting brackets.
6. U sing two large flat washers (supplied), install wood
screws or wall fastener screws.
7. T ighten screws "B" located at the top of the
mounting bracket against the hood to clamp the
position. Do not overtighten screws.
Bracket Tabs
10
Installation Instructions
Screws
"B"
Screws
"A"

5 CONNECT DUCTWORK

■ I nstall ductwork, making connections in direction of
airflow as illustrated.
■ P ush duct over the exhaust outlet until it reaches the
duct stops.
■ S ecure joints in ductwork with sheetmetal screws.
■ W rap all duct joints with duct tape for an airtight
seal.
■ U se duct tape to seal the flange connection.
CAUTION
Do not use sheet metal screws at the
hood flange connection. Doing so will prevent proper
damper operations. Seal connection with tape only.
Air Flow
Duct Tape
Over Seam
and Screw
Duct Stops
Screw
Duct Tape
Over Flange
1" = 2.5 cm; 1' = 0.3 m
31-14900 Rev. 2

Publicité

Chapitres

Table des Matières
loading

Table des Matières