EN
4.4.2
GAS FLUE CONNECTION
Gas appliances can be installed in different ways depending on the installation requirements.
4.4.3
GAS OVEN INSTALLED IN A LOCAL (TYPE A3)
4.4.4
GAS OVEN BENEATH A CEILING FAN (TYPE B23)
4.4.5
GAS OVEN DIRECTLY CONNECTED TO AN EXHAUST PIPE (TYPE B13)
INSTRUCTIONS D'UTILISATION
4.4.6
The flue gas may have high temperatures, so that the exhaust gas and hot metal parts can cause
burns.
Do not place combustible materials on the apparatus; fire hazard.
52
An incorrect flue connection may lead to a fire hazard.
It is recommended to install a gas oven beneath an extractor hood.
Install the oven according to the kitchen layout. The gas supply should only be
switched on when the extraction system is activated.
This type of installation is made connecting it to a natural draught, under a hood
or a ventilation roof. It is required a stretch of rising air.
Install the oven according to the kitchen layout. The gas supply to the oven must
only be enabled when the extraction system is activated. When the
extraction/ventilation system fails, the gas feeding of the oven will be disabled.
Convection ovens, or combined ovens with an anti-backflow valve (special
accessory), may be directly connected to an exhaust pipe. The accessory can be
ordered indicating the following references:
Oven model 061/101:19012272
Oven model 102:
19012273
The gas oven should only be enabled when the extraction system is activated.
Flues must be hermetically sealed. Use materials that are
thermally stable at temperatures of up to 400º.
Oven model 201:19012290
Oven model 202:19012291