Installation and Operation Manual
6.7.
Example 1 with cegard/Lift LX: Light curtain with dropped-out (released) latch solenoid
actuation
This example shows a simple variant, illustrating how the cegard/Lift LX can be integrated in a system without
premature door opening.
Important safety notice:
Mains power must also be available during a safety circuit interruption. Internal call signals (Innenrufe) must also
be supplied during a safety circuit interruption.
Cross reference: See section 3.3.3 for timing diagram
inside calls or
reset button
inside calls /
reset button,
reference potential
door lock signal
latch solenoid
P
N
power
supply
PE
Figure 20: Connection diagram without premature door opening
© CEDES/October 2008
to the elevator control