2. Install linear Remote Sensor
→
Push the Remote Sensor onto the actuator. The puck must be
aligned in such a way that it is inserted into the guide rail of the
Remote Sensor.
Fig. 15: Aligning the puck
→
Press the Remote Sensor all the way down as far as the actuator
and turn it into the required position.
18
Guide rail
Puck
english
Type 8798
Installation
Fastening
screws (2x)
max. 1.5 Nm
Fig. 16: Installing the linear Remote Sensor
NOTE!
Too high torque when screwing in the fastening screw does
not ensure degree of protection IP65 / IP67.
▶ The fastening screws may be tightened to a maximum torque of
1.5 Nm only.
→
Attach the Remote Sensor to the actuator using the two side fas-
tening screws. In doing so, tighten the fastening screws hand-tight
only (maximum torque: 1.5 Nm).