1.2 Technical specifications
Table 1 shows the technical specifications of the products in the range referred to in this manual.
Voltage [VAC] (Tol +10/-
20%)
Inverter power
Phases
supply
Frequency [Hz]
Current [A]
Voltage [VAC] (Tol +10/-
20%)
Phases
Frequency [Hz]
Inverter output
Current [A rms]
Max. power output [kVA]
(400 Vrms)
Mechanical power P2
Unit weight [kg]
(excluding packaging)
Mechanical
Maximum dimensions
specifications
[mm](WxHxD)
Work position
IP protection rating
Max. ambient temperature
[°C]
Max. section of lead
accepted by input and
output terminals [mm²]
Installation
Min. diameter of cable
accepted by input and
output cable glands [mm]
Max. diameter of cable
accepted by input and
output cable glands [mm]
Pressure regulation range
Control and
[bar]
operating
hydraulic
Options
specifications
Type of pressure sensors
Pressure sensor full scale
[bar]
Sensors
Type of flow sensor
supported
Connectivity
Functions and
safety devices
Safety devices
Table 1: Technical specifications
ENGLISH
Technical specifications
MCE-22/P MCE-15/P MCE-11/P
220-240
50/60
22,0
0 - V alim.
0-200
10,5
3 CV / 2,2 kW
61
220-240
1
1
50/60
18,7
0 - V alim.
3
3
0-200
8,0
2,8
2,0
2 CV / 1,5 kW
5,0
200x199x262
Any
55
50
4
6
12
1 – 95% full scale without press.
Flow sensor
Ratiometric / 4:20 mA
16 / 25 / 40
5 pulses [Vpp]
Serial interface
Multi inverter connection
Dry running
Current sensitivity on output phases
Temperature overload on internal electronics
Abnormal power supply voltages
Direct shorting between output phases
Fault on pressure sensor
220-240
1
50/60
12,0
0 - V alim.
3
0-200
6,5
1,5
1,5 CV / 1,1 kW