Manual Reset Of Error Conditions - DAB MCE-22/P Instructions Pour L'installation Et La Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 113
7.1.2
"BP" Block due to fault on pressure sensor
If the inverter detects a fault on the pressure sensor, the pump remains blocked and the error signal "BP" is
displayed. This status starts as soon as the problem is detected and is reset automatically when the correct
conditions are restored.
7.1.3
"LP" Block due to low power supply voltage
This occurs when the voltage on the line to the power supply terminal falls below 295 Vac. Reset is only
automatic when the voltage to the terminal exceeds 348 Vac.
7.1.4
"HP" Block due to high internal power supply voltage
This occurs when the internal power supply voltage has values outside the specified range. Reset is only
automatic when the voltage returns to within admissible values. This may be caused by changes in power
supply voltage or excessively sudden pump shutdown.
7.1.5
"SC" Block due to direct short circuit between the phases on the output terminal
The inverter is equipped with a protection against direct short circuits, which may occur between the phases
U, V, and W of the output terminal "PUMP". When this block signal is sent, the user can attempt reset by
pressing buttons + and – simultaneously which in any event does not have any effect until 10 seconds
has passed since the moment of the short circuit.

7.2 Manual reset of error conditions

In error status, the user can reset the fault by overriding a new attempt by pressing and releasing buttons +
and -.
7.3 Auto-reset of error conditions
In the cases of some malfunctions and block conditions, the system makes a number of attempts at
automatic reset of the electric pump.
The auto-reset system regards in particular:
-
"BL"
Block due to water failure
-
"LP"
Block due to low power supply voltage
-
"HP"
Block due to internal high voltage
-
"OT"
Block due to overheating of final power stages
-
"OB"
Block due to overheating of printed circuit
-
"OC"
Block due to current overload on electric pump motor
-
"OF"
Block due to current overload on final stages of output
-
"BP"
Block due to fault on pressure sensor
If, for example, the pump is blocked due to water supply failure, the inverter automatically starts a test
procedure to verify that the unit is effectively without water permanently. During the sequence of operations,
if a reset attempt succeeds (for example water has returned), the procedure is interrupted and normal
operation is resumed.
Table 30 shows the sequence of operations performed by the inverter for the different types of block.
ENGLISH
105

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mce-15/pMce-11/p

Table des Matières