CONTROL UNIT
2.3
Control unit diagram
BATT.1 12V 1,3Ah
BATT.2 12V 1,3Ah
Battery charger (OPTIONAL)
In order to reverse the
Battery Charger
motor direction, follow
the instructions in par.
"CHECKING MOTOR
AND GATE
OPERATING
1
DIRECTION".
24 VAC
POWER SUPPLY
TRA
F1
230V 50Hz POWER GRID SUPPLY
Caution
In order to operate on the control unit, you need to remove the clear plastic cover; then replace it at the end of interventions.
1: YELLOW - Manual function button.
2: BLUE - Manual function button also used for machine
learning performances.
3: RED - Manual function button.
S1: Manual/Automatic selector switch.
Rx Aprimatic Connector: 3-pin connector used for
Aprimatic plug-in Radio receiver connection.
Motor Connector: 5-pin connector - Includes Motor and
Encoder.
Reversing motor: Motor polarity setting jumper.
Battery Charger Connector: Plug-in connector for battery
charger (OPTIONAL).
!
Warning
Do not install the control panel
without having fi rst read the instructions !!!
N.B.: Pay particular attention to the polarity with which the
battery is connected to the control unit.
!
Warning
Any normally closed (NC) contact must be jumped if not
used.
Example:
5
6
7
8
Manual / automatic switch
Reversing Motor
Connector
Motor Connector
2
ENCODER
GND
+5VDC
MOTOR
SIGNAL
FLASHING LIGHT
24VDC 100mA Max
F N
9
ONDA 424/ONDA 624
Automatic re-closing
TR1
1
2
YELLOW BLUE RED
Manual
Automatic
S1
MEMORY MODULE
POWER LED
BLINK-LIGHT LED
+ -
Batt.1-Batt.2: Back-up batteries 12V 1,3Ah (OPTIONAL).
TR1: Trimmer for setting pause time before automatic closing
(see relevant paragraph).
TR2: Trimmer for setting torque threshold (see relevant paragraph).
TRA: Transformer 230V -24V.
F1: Safety fuse 3,15A Delayed.
Power LED: Lights up when the power is ON.
BLINK-LIGHT LED: Lights up in the same way as the
fl ashing light and is used to check the remote control unit
self-learning.
11-pin + 2 pin terminal boards:
TERMINAL
1 - 2
Flashing light output
3
positive power TX and RX
4
5
common for push-button and safety devices
and
6*
7*
8
9
RX photocell input contact
10
START apertura pedonale
Step-by-step START
11
12 - 13
* to reverse in case of closing toward left (see the reversing motor jumpers)
- 14 -
Maximum torque threshold setting
Radio module
TR2
3
Aprimatic RX CONNECTOR
Radioreciver Module
(OPTIONAL)
Antenna braid
ANTENNA
START (Step by step mode)
START Pedestrian opening
Photocell contact
Stop
Opening limit switch
Closing limit switch
FUNCTION
negative power TX
GND (only TX)
negative power RX
closing limit switch
Normally Closed
Normally Closed
opening limit switch
STOP input
Normally Closed
Normally Closed
Normally Open
Normally Open
push-button input
antenna inputs
SETTING
24 VDC
+24 VDC
GND