Description; Block Diagram Of The Device; Technical Data; Installation - Aprimatic T3S Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1. DESCRIPTION

This is an Aprimatic microprocessor unit for driving a motor with a maximum power of 250
Watt.
The T3S version incorporate a radioreceiver module.

1.1 BLOCK DIAGRAM OF THE DEVICE

RV1 Approach speed trimmer
RV2 Reverse sensitivity trimmer
RV3 Pause time trimmer
RV4 Operating time trimmer
SW1 DIP-SWITCH
K1
Motor terminal board + mains
voltage (IN)
K2
Signal/command terminal board
K3
Connector for decoding badge
reader, or coded keypad, or Aprimatic
model Radio receiver (ONLY for T3E)
K4
Earth connection terminal board
K5
Courtesy light connector
RL1 Direction relay
RL2 Courtesy light relay
RL3 Motor relay
TF1 Transformer
JP1 Slowing type

1.2 TECHNICAL DATA

Voltage
230 VAC (+6% - 10%)
Frequency
50HZ
Fuse protection
F1
F5A motor protection quick-acting fuse
F2
F200mA transformer primary circuit quick-acting fuse
F3
F500mA 24V accessories quick-acting fuse
Device stand-by consumption
15W
Device max. consumption
680W
Operating temperature
-20°C +70°C
Storing temperature
-40°C +85°C
Relative humidity
90% max. 90% (non-condensing)
Sealing
IP55 (only for IP55 boxes)
LD1 Power on (green)
LD2 Red LED, lights up with LD4 when
start is given from card
LD3 Red LED, open/close safety
LD4 Red LED, lights up when start is given
from receiver (ONLY for T3S)
LD5 Red LED, stop
LD6 Red LED, photocell
LD7 Red LED, limit switch
LD8 Red LED, receiver
LD9 Anti-crush safety triggered LED (red)
JP5-8
Receiver output channel selection
jumpers (ONLY for T3S)
J2
Receiver memory module connector
(ONLY for T3S)
BZ1 Buzzer (ONLY for T3S)
CON1 Aerial terminal block (ONLY for T3S)
SW2 Receiver delete button (ONLY for T3S)
(with motors and accessories connected and functioning)
5 4 3 2 1
1 2 3 4
5 6 7 8 9 10
TRIMMER REGULATION
= more sensitive = less thrust force
= less sensitive = more thrust force

2. INSTALLATION

CAUTION - The product must only be installed by qualified servicing and/or installation
personnel.
CAUTION - The electrical system must comply with current regulations in the country
where the product is installed.
CAUTION - Always make sure that the mains power supply is turned OFF before
opening the container. Ensure that there is a good earthing system. Always
connect it to the relative terminals.
T3E
1 2 3 4
5 6
ATTENTION !
If an HYDRAULIC OPERATOR is used:
set RV2 at the end of the scale range towards
switch S6 to the ON position.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

T3e

Table des Matières