II - CHARGE :
1. Make sure to disconnect the charger from the battery, set the on/off switch on the « off » position.
2. Connect the charger's red clamp to the battery's positive terminal.
3. Connect the charger's black clamp to the battery's negative terminal.
4. Select the voltage output (CA360 only) et the charging speed (CA150 and CA360) on the charger.
5. Set the charger's on/off switch on the "on" position
III - ADVICE
◊ Connection and disconnection
Disconnect from the battery all electronic system during the charge (do not charge the battery when it is connected
on the car) (CA 360 in manual mode only).
◊ Starting
Do not start the vehicle with the charger connected to the battery. This will blow the fuse.
◊ Problems
A quick charge can cause problems:
- The fuse blows and stops the charge.
- The OK light indicator is on but without the battery being charged, it starts and stops regularly.
In this case restart the charger after selecting the slowest charging mode available.
◊ Thermal protection
The charger is fitted with a thermostat. If it gets too hot, the charger will stop working. Place the unit in a ventilated
room, wait until it cools down to turn the charger on (wait 10-20 minutes)
◊ Fuse
The fuse will protect the unit in the following instances:
- Polarity reversal or clamps in short-circuit.
- Starting the vehicle whilst the battery is connected to the charger.
- Charging current is in boost mode for too long or too high and above the nominal current in standard charge mode.
In case of a fuse break, disconnect the clamps from the battery, switch the unit off, change the fuse, set the charger to
the minimum charge output available and reconnect everything as instructed above.
Primary fuse
Secondary fuse
◊ Sulphated battery
Batterries without a regular maintenance can be sulphated but in some case they can be recovered. If a battery is
sulphated the needle of the ammeter stays on 0. In this case set the charger to a high current output and monitor the
charge every hour. If after 5 hours the needle hasn't moved the battery cannot be recovered.
TROUBLESHOOTING
Symptoms
The ON/OFF button does not
switch on when set to ON.
CA 150, 360
CA 150
(No Gys reference for sells)
Cylindrical 5×20mm - T3.15A
Littelfuse reference : 02153.15MXP
Gys reference : 054516
Type : ATOF blade - 25A
Littelfuse reference : 287025.PXPV
Causes
No mains voltage
(No Gys reference for sells)
Cylindrical 5× 20mm - T5A
Littelfuse reference : 0215005.MXP
Gys reference : 054622
Type: BF1 – M5 - 32V 50A
Littelfuse reference : 153.5631.5502
Remedies
Check that the power cord is plugged to a 230V
50/60Hz socket. Check the power supply
network.