4. Alarm handling

There are three different alarm levels; information
alarms, heat pump circuit alarm and system alarm.
Three different alarms can be stored at the same time.
Each alarm must be reset by pressing the control button
at the control panel.
The information alarms do not stop the heat pump, but
informs the user that there is a disturbance that has to
be solved as soon as possible (Alarm no: 8, 9 and 10).
The heat pump circuit alarms stop the hot water
production with the compressor and switches to
100 % supplementary heating sources (immersion
heater or external boiler). (Alarm No: 3, 4, 5 and 6).
System alarms blocks the whole product. (Alarm no: 1
and 2).
The alarms are presented in the alarm menu, where
also the alarms are confirmed. Each alarm must be
confirmed before normal operation is possible. If no
action is taken before an alarm is confirmed the alarm
will still be on. In the case several simultaneous alarms,
they are placed in a row. The alarms will be presented in
order of importance.
Alarm
Alarm lamps:
Number
No. 25
1
X
(red)
2
X
(red)
3
X
(red)
4
X
(red)
5
X
(red)
6
X
(red)
7
X
(red)
8
X
(red)
9
X
(red)
10
X
(red)
16
CTC EcoWater
Alarm name
No.26
X
Short circuit in the temperature
(red)
sensor in the top of the tank.
X
Temperature sensor in the top of
(red)
the tank is switched off.
Short circuit in the temperature
sensor for the evaporator.
Temperature sensor for the
evaporator is switched off.
First pressure switch alarm
Second pressure switch alarm
N/A
Short circuit in temperature sensor
"Temp 1".
Automatic sacrificial anode
Legionella temperature not reached
Pressure switch alarms
Pressure switch alarm (5, 6) will be handled in the
following way;
At the first break, alarm no. 5 will show in the display
and lamp (25) flashes. The heat pump will stop and
automatically restart. If the error is eliminated, the lamp
(25) will switch to flash orange, and after the alarm is
confirmed constant orange or green.
If a second alarm occurs less than 6 hours after the
first alarm, alarm no. 6 will show in the display and the
heat pump will stop. The heat pump can now only be
restarted by confirming the alarm. With alarm no. 6 the
lamp (25) will flash red. When the pressure switch is
controlled and repaired the alarm can be confirmed and
the product restarted.
Comment
Complete product is blocked
Complete product is blocked
Compressor stops
Compressor stops
Compressor stops and starts again
automatically.
Compressor stops and actions are needed
before alarm confirmation and restart.
N/A
Sensor for external boiler or outdoor
temperature. Information alarm.
Change anode. Information alarm.
Information alarm.