"FanPause" is a function for preventing the overflow of condensation water
if the heat pump is placed in a room with high air humidity. When activated,
the fan will stop either for 15 or 30 seconds per hour unless the heat pump
has reached its set point and the compressor and fan stops automatically.
If "FanCon" is activated, then the "FanPause" function still works. When the
set point has decreased enough, the compressor and fan start again and
the "FanPause" function is automatically activated from the moment the
compressor and fan start. If "FanPause" is set to "Off", then the function is
deactivated.
2.11

Electrical installation

The heat pump is to be used on 230V, 1N~ (single phase). The product is
equipped with a 2 m power supply cord, 3 x 1.5 mm
The power supply shall be connected to a socket with a security breaker. For
details regarding electrical specification see chapter "Technical data".
2.12

Wiring diagram

S1
Control panel
N3
Thermostat Heating element
C1A Operation capacitor fan
C1B Operation capacitor
Compressor
C2
Capacitor fan speed
2
and a European socket.
C4
Motor protector
E1
Heating element
F1
High pressure switch
F2
Thermostatic max switch
M1
Compressor
English
1. Orange
2. Red
3. Yellow/
Green
4. Blue
5. Brown
6. Black
7. Grey
8. White
M2
Fan
MV1 Solenoid valve
K1
Start relay compressor
X
X1 / X2 = Earth
SA
Automatic sacrificial anode
CTC EcoWater
13