Troubleshooting guide, Truma VarioHeat
Fault
Cause
# 2
Flame not recognised:
– Gas cylinder or quick-acting valve in the gas
supply line closed
– Gas pressure regulation system iced up
– Butane content in the gas cylinder too high
– Combustion air infeed or exhaust outlet is
sealed
# 7
– Room temperature sensor not connected or
cable defective
# 11
– Temperature cutout has been triggered
# 25
– Overvoltage > 16.4 V
# 26
– Low voltage,battery voltage too low < 10 V
# 27
– Warm air outlets blocked
– Circulated air intake blocked
– End outlets EN closed up
# 28
– Open window above cowl (window switch)
# 29
– Risk of low voltage, battery voltage too low
< 10.4 V
# 32
– Motor wear limit will be reached soon
# 255
– No connection between heater and
control panel
– Control panel cable or main fuse defective
If these measures do not remedy the fault or if fault codes are displayed that you cannot find in the troubleshooting
guide, contact Truma Service.
Troubleshooting guide (air conditioning system)
Fault code Cause
# 1
Failure (short circuit or broken cable), room temperature
sensor
# 2
Ice sensor failure – internal
# 4
Ice sensor failure – external (if present)
# 8
IR receiver unplugged or cable broken
If these measures do not remedy the fault or if fault codes are displayed that you cannot find in the troubleshooting
guide, contact Truma Service.
28
Remedy
– Check gas supply and open valves
– Use EisEx regulator heater
– Use propane (butane is unsuitable for heating, particularly
at temperatures below 10 °C)
– Inspect openings for obstructions (slush, ice, leaves, etc.)
and remove any obstructions
– Contact Truma Service
– Contact Truma Service
– Check the battery voltage and voltage sources such as the
charger
– Charge battery and replace old battery if necessary
– Remove blockage
– Remove blockage
– Open end outlets EN
– Close window
– Charge battery
– Contact Truma Service
– Contact Truma Service
Remedy
Contact Truma Service
Inspect the filter and replace it if necessary
Keep the air inlets / outlets on the roof free of obstructions such as
leaves