Withstand capacity relative to
fast power supply transients
Withstand capacity relative to
polarity inversions on power
Fuse protection
Low level on opto-coupler input
High level on opto-coupler input
Maximum voltage level on an
input with no damage
Withstand capacity relative to
fast power supply transients with
direct connection
Withstand capacity relative to
electrostatic discharges
Withstand capacity relative to
electromagnetic fi elds
Operating temperature range
Storage temperature range
Maximum frequency of a signal
on an input (continuous or
intermittent transmission mode)
(1) = 1mW mode not available for IST transceivers
ISIS - 331260D
Without damage
30V
Fuse 250 mA
DC Voltage < 2 V
DC Voltage > 3 V
30 V
+2KV
± 4 kV
10v/m
-20°C to +50°C
-30°C to 70°C
1mW mode (1) = 10Hz max
10mW mode = 0,5Hz max