Installation

Canopy Ventilation Recommendations

18"-24"
457-610mm
Capture Velocity
(MIN)
B
Dimension
A
B (MIN)
C (MIN)
D
E (MIN)
F
Exhaust Flow
AFF = Above Finished Floor
* Hood dimensions shown are for island mount ‑ Size reductions may be possible for wall mount units.
NOTE: Hood dimensions and the positioning of the hood
over the oven will vary with hood manufacturers.
12
A
Capture Area
Single or Double Stack
96 in (2438 mm)
8 in (203 mm)
22 in (559 mm)
80 in (2032 mm)
12 in (305 mm)
80 in (2032 mm)
1400 – 1600 CFM
Capture
Velocity
(MIN)
C
Triple Stack *
10 ft (3039 mm)
22 in (559 mm)
22 in (559 mm)
6 ft 8 in (2032 mm)
12 in (304 mm)
6 ft 8 in AFF (2032 mm)
NOTE: Lincoln can provide oven spec sheets that show
the dimensions of the oven, kW or BTU ratings and other
information that will be useful to both the ventilation hood
supplier and the HVAC contractor.
D
Capture Area
Part Number 11020000487 Rev A (2/16)
Section 2
(MIN)
E
F