Electrical Service-All Models With Electric heat
UTILITY SPECIFICATIONS REQUIRED - ELECTRIC
Model
3240-xxx-B-Kxxxx
3240-xxx-D-Kxxxx
3240-xxx-G-Kxxx
3240-xxx-R-Kxxxx
3240-xxx-V-Kxxxx
3240-xxx-W-Kxxxx
Electrical Supply for Australia:
Single Phase: 240VAC, 50Hz / 20 Amp: one neutral & one earth/ground.
Three Phase: 240/415 VAC / 20 Amp; three active, one neutral & one earth/ground.
** In Australia, use a 10 Amp General Purpose Outlet
All ovens require separate service and dedicated neutral.
Part Number 11020000487 Rev A (2/16)
Energy
Power
Voltage
400/230
Electric
24 kW
VAC
380/220
Electric
24 kW
VAC
415/240
Electric
24 kW
VAC
Electric
24 kW
208 VAC 66 Amps
Electric
24 kW
240 VAC 58 Amps
Electric
24 kW
220 VAC 63 Amps
Current
Phase
40 Amps
3
50 Hz
41 Amps
3
50 Hz
38 Amps
3
50 Hz
3
60 Hz
3
60 Hz
3
60 Hz
Recommended Electrical
Hz
Specifications
4 Wires, 3 Pole
1N + 1G
4 Wires, 3 Pole
1N + 1G
4 Wires, 3 Pole
1N + 1G
3 Wires, 3 Pole + G
3 Wires, 3 Poles + G
3 Wires, 3 Poles + G