TECHNICAL DATA

MODEL
TYP
OUTPUT
(1)
DELIVERY
(1)
FUEL
Gas pressure at maximum delivery
OPERATION
NOZZLES
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTORS
FAN MOTOR
(Direct starting for RLS300)
PUMP MOTOR
IGNITION TRANSFORMER
PUMP
delivery at 16.5 bar (kg/h)
pressure range (bar)
fuel temperatur (°C max)
ELECTRICAL POWER CONSUMPTION (LIGHT OIL)
ELECTRICAL POWER CONSUMPTION (GAS)
ELECTRICAL PROTECTION
CONFORMITY TO EEC DIRECTIVES
NOISE LEVELS
(3)
APPROVAL
Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(1)
Pressure at test point 5)(A)p.12 with zero pressure in the combustion chamber and maximum burner output.
(2)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
(3)

ACCESSORIES

(optional)
OUTPUT POWER REGULATOR KIT:
rates between the low and high flame output position, thus ensuring stable operating conditions in terms of temperature or pressure. Two compo-
nents should be ordered: • Power regulator to install to the burner; • probe to install to the boiler.
PARAMETER TO BE CHECKED
Temperature
Pressure
• KIT AZL (display and operating unit)
• PRESSURE SWITCH KIT (for leak detection control)
• KIT SOFTWARE INTERFACE
• CONTINUOUS PURGING KIT
• SOUNDPROOFING BOX KIT
• GAS TRAIN ACCORDING TO REGULATION EN 676: see page 26.
Note.
Riello S.p.a. declines all responsibility for the addition of safety devices not provided for herein.
MIN - MAX
- Gas: G20/G25
(2)
number
°C max
V1 - V2
I1 - I2
kW max
kW max
class 3 (EN 676)
class 2 (EN 267)
Under modulating operation, the burner automatically adapts to one of an infinite number of firing
Range
- 100...+ 500°C
0...2.5 bar
0...16 bar
RLS 300/E MX
782 T1
kW
600 ÷ 3650
kg/h
50 ÷ 309
LIGHT OIL, viscosity at 20 °C: 6 mm
NATURAL GAS: G20 (methane) - G21 - G22 - G23 - G25
mbar
- Continuous / Intermittent (min. 1 stop in 24 hours)
- Progressive two-stage or modulating by kit (see ACCESSOIRES)
1
Boilers: water, steam, diathermic oil
°C
0 - 40
60
3N ~ 400 / 230V +/-10% 50 Hz
rpm
2900
V
230/400
kW
4.5
A
15.8 - 9.1
V
kW
A
7.5
IP 54
90/396 - 89/336 - 2004/108 - 73/23 - 2006/95
dBA
80
CE
0085BR0471
PROBE
Type
PT 100
Output probe
4...20 mA
Code 3010355
Code 3010344
Code 3010388
Code 3010094
Code 3010376
8
RLS 400/E MX
783 T1
800 ÷ 4300
70 ÷ 365
2
/s (1.5 °E - 6 cSt)
2900
400/680
380/415 - 660/718
7.5
16 - 9
230/400
1.5
6.4/3.7
230 V - 2 x 5 kV
1.9 A - 35 mA
560
7 - 40
140
11.5
85
0085BR0472
POWER REGULATOR
Code
Type
3010110
RWF40 BASIC
3010213
RWF40 HIGH
3010214
RLS 500/E MX
1300 T1
1120 ÷ 5050
95 ÷ 425
2900
12
23 - 13.2
-
7 - 30
140
15
13
88
In progress
Code
3010356
3010357