Maximum suction lift (continuous operation) for media with
maximum permissible viscosity
Pump type
DMH 280
DMH 281
DMH 283
DMH 285
DMH 286
DMH 287
DMH 288
3.5 Sound pressure level
Pump type
DMH 280
DMH 281
DMH 283
DMH 285
DMH 286
DMH 287
DMH 288
* Testing according to DIN 45635-01-KL3.
3.6 Electrical data
3.6.1 Enclosure class
The enclosure class depends on the motor variant selected, see
motor nameplate.
The specified enclosure class can only be ensured if the power
supply cable is connected with the same degree of protection.
Pumps with electronics: The enclosure class is only met if the
sockets are protected! The data regarding the enclosure class
applies to pumps with correctly inserted plugs or screwed-on caps.
3.6.2 Motor
Version: see motor and pump nameplates.
3.7 AR control unit
Functions of pumps with electronics:
•
"Continuous operation" button for function test and dosing
head deaeration
•
memory function (stores a maximum of 65,000 pulses)
•
two-stage tank-empty signal (e.g. via Grundfos tank empty sensor)
•
stroke signal/pre-empty signal (adjustable), e.g. as a feedback
to the control room
•
dosing controller function (only with sensor - optional)
•
diaphragm leakage detection (only with sensor - optional)
•
access-code-protected settings
•
remote on/off
•
hall sensor
•
operating hours counter
•
motor monitoring.
Operating modes:
•
manual
Stroke frequency: manually adjustable between zero and
maximum
•
contact signal control
Multiplier (1:n) and divisor (n:1)
•
current signal control 0-20 mA/4-20 mA
Adjustment of stroke frequency proportional to the current
signal. Weighting of current input.
Maximum suction lift
[m WC]
Flooded suction
Flooded suction
Flooded suction
Flooded suction
Flooded suction
Flooded suction
Flooded suction
55 ± 5 dB(A)*
55 ± 5 dB(A)*
65 ± 5 dB(A)*
75 ± 5 dB(A)*
75 ± 5 dB(A)*
75 ± 5 dB(A)*
65 ± 5 dB(A)*
3.7.1 Inputs and outputs
Inputs
Contact signal
Current 0-20 mA
Remote on/off
Two-stage tank-empty signal
Dosing controller and diaphragm leakage sensor
Outputs
Current 0-20 mA
Error signal
Stroke signal
Pre-empty signal
AR control unit factory settings
•
Inputs and outputs: NO (normally open)
or
•
inputs and outputs: NC (normally closed).
3.8 Required energy
Power supply for AC voltage
Permissible deviation from rated
Rated voltage
230/400 V
240/415 V
115 V
Maximum permissible mains impedance
(0.084 + j 0.084) Ohm (testing according to DIN EN 61000-3-11).
These details apply to 50 Hz.
3.9 Ambient and operating conditions
•
Permissible air humidity: max. relative humidity:
70 % at +40 °C, 90 % at +35 °C.
The installation site must be under cover!
Caution
Do not install outdoors!
3.9.1 DMH with motor labelled for coolant temperature -20 °C
≤ T
≤ 40 °C
amb
•
Permissible ambient temperature: 0 °C (standard) to +40 °C
(for an installation height up to 1000 m above sea level)
•
Pumps with minimum T
amb
•
Permissible storage temperature: -20 °C to +50 °C.
3.9.2 DMH with motor labelled for coolant temperature -20 °C
≤ T
≤ 55 °C and with dosing head material
amb
stainless steel or PVDF
•
Permissible ambient temperature: 0 °C (standard) to +55 °C
(for an installation height up to 1000 m above sea level)
•
Pumps with minimum T
amb
•
Permissible storage temperature: -20 °C to +55 °C.
Observe the nameplate of the motor.
Note
Pumps with AR control unit only
Maximum permissible mains impedance: 0.084 + j 0.084 Ω
(testing according to EN 61000-3-11).
Maximum load: 12 V, 5 mA
Maximum load: 22 Ω
Maximum load: 12 V, 5 mA
Maximum load: 12 V, 5 mA
Maximum load: 350 Ω
Maximum ohmic load:
50 VDC/75 VAC, 0.5 A
Contact time/stroke: 200 ms
Maximum ohmic load:
50 VDC/75 VAC, 0.5 A
value
± 10 %
± 10 %
± 10 %
-20 °C available on request
-20 °C available on request
11