ON
START
5.
Immediately after the engine starts, re-
lease the main switch to return it to "
(on). NOTICE: Never turn the main
switch to "
gine is running. Do not keep the start-
er motor turning for more than 5
seconds. If the starter motor is turned
continuously for more than 5 seconds,
the battery will be quickly discharged,
thus making it impossible to start the
engine. The starter can also be dam-
aged. If the engine will not start after 5
seconds of cranking, return the main
switch to "
" (on), wait 10 seconds,
then crank the engine again.
EMU36511

Checks after starting engine

EMU41361

Cooling water

Check for a steady flow of water from the
cooling water pilot hole. A continuous flow of
water from the cooling water pilot hole shows
that the water pump is pumping water
through the cooling water passages.
TIP:
When the engine is started, there may be a
slight delay before water flows from the cool-
ing water pilot hole.
ZMU05830
" (start) while the en-
[ECM00193]
ECM02251
NOTICE
If water is not flowing out of the cooling
water pilot hole at all times while the en-
gine is running, overheating and serious
damage could occur. Stop the engine and
check whether the cooling water inlet on
the lower case or the cooling water pilot
hole is blocked. Consult your Yamaha
dealer if the problem cannot be located
and corrected.
"
1
1. Cooling water pilot hole
EMU27671

Warming up engine

EMU41234

Procedure for warming up engine

1.
After starting the engine, warm up the
engine until the engine speed stabilizes
at idle speed to provide maximum oper-
ating performance and acceleration.
NOTICE: Failure to do so will shorten
engine life.
Idle speed (in neutral):
700–800 r/min
2.
Check that the low oil pressure-alert indi-
cator remains off. NOTICE: If the low oil
pressure-alert indicator blinks after
the engine starts, stop the engine.
Operation
ZMU08095
[ECM04550]