• InFo Display

Information
INFO
display
8
Serial
(ODE
communication
code
9
updt
Software
version
10
CFG
Control parameters
Enabling self-
s. t vn
tuning,
autotuning,
softstart
15
Proportional band for
h pb
heating or hysteresis on
-
ON-OFF action
16
h it
Integral time
-
for heating
17
h dt
Derivative time
-
for heating
18
h. p . x i
Maximum power limit
for heating
19
h. p . l o
Minimum power limit for
heating (not available for
double heat/cool action)
254
(. m ed
Cooling medium
97
C.MEd
0
Air
1
Oil
2
Water
Setpoint for cooling
c. s p. o
relative to heating
setpoint
20
Proportional band for
c pb
cooling or hysteresis for
-
ON/OFF control
21
c it
Integral time for cooling
-
22
c dt
Derivative time
-
for cooling
23
c. p . x i
Maximum power limit
for cooling
24
Minimum power limit for
c. p . l o
cooling (not available for
heating/cooling double
action)
255
prot
Software
protection code
11
Self
er. n r
diagnostic
error
code
12
• CFG
S.tun Continuous
Self-tuning
Softstart
autotuning
0
NO
NO
NO
1
YES
NO
NO
2
NO
YES
NO
3
YES
YES
NO
4
NO
NO
YES
5
YES
NO
YES
6
-
-
-
7
-
-
-
8
WAIT
NO
NO
9
GO
NO
NO
10
WAIT
YES
NO
11
GO
YES
NO
12
WAIT
NO
YES
13
GO
NO
YES
0.0 ... 999.9%
full scale
0.00 ... 99.99 min
0.00 ... 99.99 min
0.0 ... 100.0%
0.0 ... 100.0%
0 ... 2
Relative gain (Rg)
(see applicable note)
1
0,8
0,4
± 25.0% f.s.
0.0 ... 999.9%
full scale
0.00 ... 99.99 min
0.00 ... 99.99 min
0.0 ... 100.0%
0.0 ... 100.0%
rst
-
25
p. r st
0 No Error
1 Lo
26
2 Hi
3 ERR
a. r st
4 SBR
27
ffd
-
28
soft
29
xys. i
30
xys. 2
31
xys. 3
xb t
-
33
lba. t
34
lba. p
35
Fa(. p
36
gr. s p
216
(*)
LBA alarm may be reset by simultaneously pressing
switching to Manual.
Note:
h_Pb, h_it, h_dt, h.P.Hi, hPLo, c_Pb, c_it, c_dt, c.P.Hi, c.P.Lo parameters are "read only" if the option
"control parameter groups" has been selected (showing current values)
c_Pb, c_it, c_dt parameters are "read only" if the option "relative gain heat/cool control" (Ctrl = 14) has
been selected.
21
-999 ... 999
Manual reset
scale points
Reset power
-100.0 ... 100.0%
0 ... 9999
Antireset
scale points
Feedforward
-100.0 ... 100.0%
Softstart time
0.0 ... 500.0 min
± 999
Alarm 1 hysteresis
scale points
± 999
Alarm 2 hysteresis
scale points
± 999
Alarm 3 hysteresis
scale points
Waiting time for HB alarm
0 ... 999
intervention
seconds
(Value has to be higher than cycle time value of
output to which HB alarm is assigned)
Waiting time for LBA alarm intervention
(Set to "0" to disable LBA alarm)
Power limit for LBA
alarm condition
Power output in fault condition
(when probe is faulty)
Set gradient
0.0...999.9 digit/min.
(digit / sec see SP.ty)
(see applicable note)
∆ + ∇
keys when OutP is displayed or by
(*)
0.0 ... 500.0 min
-100.0 ... 100.0%
(*)
ON / OFF
-100.0 ... 100.0%
ON / OFF