Les langues disponibles

4.8.2

LOCKOUT DUE TO FIRING FAILURE

P
TL
t
1
t
2
MV
M
I
V1
F
LED
4.8.3
LOCKOUT DUE TO EXTRANEOUS LIGHT
DURING PRE-PURGING
P
TL
t
1
t
2
MV
M
I
V1
F
Green
LED
3280
t
3
t
4i
t
s
Green+Yellow
Green
t
3
t
s
t
3l
.
Lockout
Red+Yellow
KEY TO LAY-OUT
F
– Flame detector
– Ignition transformer
I
LED – Reset button LED indicating operating
status
MV – Fan motor
TL – Limit thermostat
V1 – Oil valve
Red
D7360
OPERATING TIMES
t1
max
max
t1I
t2
t3
max
t3I
ts
Time is expressed in seconds
D7361
10 GB
Red
Green + Yellow slow blinking
Green + Yellow fast blinking
Green
Green + Yellow medium blinking
Red + Yellow fast blinking
Yellow fast blinking
1
t4i
30
t5i
-
3
max
t4I
-
15
max
t6
1
max
t6I
-
5
t7
-
8
-
3
1
360
30
-
120

Publicité