VIII
– Maintenance menu
To access the maintenance menu, open the configuration menu by pressing and holding "S",
then "+" for 3 seconds. Release both keys, then press and hold "S", then "+" again for 7 seconds.
8.1 AFNOR synchronisation
+
S
+
Hold down for 3 seconds
Open configuration menu
+
S
Hold down for 7 seconds
+
Software version
May differ from the version shown depending on the date of purchase.
S
+
S
+
S
S
+
S
+
S
Display test (tests for correct functioning of all LEDs)
S
End of menu
+
Select mode: cod or loc (default cod)
Cod: the clock displays the time code data received, without modification.
Loc: the clock calculates and displays local time using the time code data received
plus its summer/winter time changeover and time difference settings.
+
+
S
Reset clock (enabled if "rstY" is selected)
Restore factory settings (enabled if "dF Y" is selected)
Select synchronisation mode
AFn: AFNOR (default)
AFnI: Independent AFNOR (the clock operates using its internal time base)
IrIG: IRIG-B
+
+
+
+
EN
+
Select time zone
+
(default Eur)
+
13