Bodet Style 5S Hôpital Notice D'installation page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2) Mounting with back cover
According to the model of the clock make the cut-out following the dimensions listed in table below
Style 5S OP
Style 7S OP
Dimensions in mm
a) Insert the back cover in the cut-out in order to mark the position of the 6 mountig screws.
b) Remove the back cover and drill 2 holes Ø 6 mm (
mounting
c) Drill 4 holes Ø 10mm (
d) Feed the power cable, the synchronisation cable and the keypad cable throught the cut-out and
cable glands of the back cover.
e) Fix the back cover to the wall with the 2 screws Ø 4mm
f) Connect the clock, adjust the brightness (page 7) and set the time (refer to page 10)
g) Fix the clock to the back cover with the 4 screws Ø 4mm
CAUTION: do not fit a DHF clock in a metal back cover or equivalent.
6
A
B
400
46
440
Y
) to make room for the back cover clock mounting rivets.
Installation with back cover
C
365
404
Y
X
Y
X
) to insert the wall plugs.for the back cover
D
E
68
107
85
123
Back cover mounting screws