MonoControl CS installation and connection
The MonoControl CS must be installed in such a way that the
high-pressure hose connection is in the highest possible location,
which must be at least higher than the cylinder valve level (broken line).
The high-pressure hoses must slope downwards all the way to the
cylinder valve.
Figure 2
Installation above the cylinder valve makes it more difficult for
gas in the liquid phase to penetrate the gas pressure regulator,
particularly while driving.
The MonoControl CS is connected to the high-pressure hose via the
M20 x 1.5 (G.13) male thread on the inlet side and is connected to the
gas pipe via an 8 mm or 10 mm olive screw connection (H.9) on the
outlet side.
The MonoControl CS is intended for installation in the gas cylinder
box of the caravan or motor home.
When it is being used outdoors, the MonoControl CS must be
protected from the elements and dripping water by a protec-
tion hood (not included).
14