Translation of the original instructions
INSTALLATION
These machines can work in difficult environments. However it is essential to follow the instructions listed below :
• Put the machine on a floor with a maximum inclination of 10°.
• Provide adequate space for the machine's ventilation and easy access to the controls.
• The machine must be protected form the heavy rain and the sun's rays .
• The machine must not be used in an area with metal dusts.
• The machine protection level is IP21, which means :
- Protection against acess to dangerous parts from solid bodies of a ≥12.5mm diameter and,
- Protection against vertically falling drops.
• The power cables, extensions and welding cables must be fully uncoiled to prevent overheating.
The manufacturer does not accept responsilbity for damage resulting from incorrect and/or
dangerous use of the machine .
MAINTENANCE / RECOMMENDATIONS
• Maintenance should only be carried out by a qualified person.
• Ensure the machine is unplugged, and that the ventilator inside has stopped before
carrying out maintenance work. DANGER High Voltage and Currents inside the machine.
Periodical maintenance:
• Periodically remove the cover and dust with an air gun. You are advised to have the electrical connections
checked by a qualified person, with an insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced
by the manufacturer, an after sales service or a qualified person to prevent danger.
• Do not obstruct the machine's air intake, to allow air circulation.
• Check that the torch does not have any cracks or exposed wires.
• Check that the consumables are installed properly and not worn .
• Leave the outlets of the source of free welding current for the inlet and the air outlet.
• Do not use this equipment to thaw pipes, to charge batteries, or to start any engine.
INSTALLATION – PRODUCT OPERATION
DESCRIPTION
Thank you for chosing this machine. To get the best use from your machine, please read the following carefully :
The Easymig range are semi-automatic MIG/MAG, MMA and flux cored wire welding stations. They are manual
settings machine, with the help of the table printed on the product. They are recommended for welding steel,
stainless steel and aluminium.
ELECTRICITY SUPPLY
The absorbed current (I1eff) is indicated on the device at maximum usage. Check that the power supply and
its protection (fuse and/or circuit breaker) are compatible with the current needed for use. In some countries, it
might be necessary to change the plug to allow maximum performance. The device must be installed so that the
mains socket is accessible.
Do not use an extension cable with a diameter of less than 1.5mm². Easymig is delivered with a 16amp plug
(TYPE CEE7-7).
This machine must be connected to an EARTHED power supply 230V, 50/60 Hz, and protected by a 16A circuit