Faults, cause, remedy

Fault
X-zone cannot be charged.
X-zone cannot be charged with an
intrinsically safe power supply.
Battery life is low.
No wireless connection between the
X-zone devices.
Cable connection is not functioning.
Alarm contact is not switching.
Pump operation is not functioning.
Pump fault during operation.
Dräger X-zone 5500 / 5800
Cause
Charging unit plug is not in correct
contact with the X-zone device.
Inductive charging is not functioning
correctly as the distance between the
X-zone device and the charging cradle is
too great.
Plug not in correct contact.
No voltage supplied by supply unit.
Battery is not fully charged.
Battery not regularly charged.
Outdoor temperature is too low.
Outdoor temperature is very high.
Battery is faulty.
Inductive charging is performing poorly
as the distance between the X-zone
device and the charging cradle is too
great.
Wireless function is not activated.
X-zone devices are very far apart.
Wireless connection is made more
difficult by the industrial environment:
e. g. steel walls.
X-zone devices are covered by
conductive materials (e.g. metal grids).
Network number of the X-zone devices
varies.
Wireless frequency of the X-zone
devices varies.
Cable plug is not correctly plugged in,
cable assignment is incorrect or cable is
broken.
Cable plug is not correctly plugged in,
cable assignment is incorrect or cable is
broken.
Incorrect holder (diffusion) in position.
Condensate formation with cold and
damp intake air.
Pump outside the specified range.
Faults, cause, remedy
Remedy
Ensure that the charging unit plug is
correctly plugged in.
Check the battery LED.
Check the distance, remove any dirt if
necessary.
Make sure the plug is inserted correctly.
Where applicable, clear the area of any
contamination.
Check supply unit. Where applicable,
switch on supply unit.
Charge battery for at least 14 h - 24 Ah.
Charge battery regularly even when
switched off, at least every 2 months.
Warm up the X-zone device.
Use safety housing where appropriate.
Have the battery checked by
DrägerService.
Check the distance, remove any dirt if
necessary.
Activate the wireless function using the
Dräger CC-Vision PC software (see
Chapter 11 on Page 60).
Position the X-zone devices more closely
together.
Position additional devices in the chain.
Place X-zone devices at a higher position,
use base (order no. 83 20 645) if
necessary.
Position X-zone more closely together.
Place additional devices into the chain.
Connect the X-zone with a communication
cable (see Chapter 5 on Page 51).
Ensure there are no obstructions.
Use X-zone devices with the same
network numbers. The network number
can be configured using the Dräger
CC-Vision PC software (see Chapter 11
on Page 60).
Use X-zone devices with the same
wireless frequency.
Check cable connection and assignment.
Ensure that the cable plug is correctly
plugged in.
Check cable connection and assignment.
Ensure that the cable plug is correctly
plugged in.
Position the holder (pump).
Use hose set with water trap (order no.
83 21 527).
Have the pump checked by
DrägerService.