Professional Balance Charger, Discharger
8
Capacity Cut-Off
ON
–
+
DEC
INC
DEC
9
Key Beep
Buzzer
DEC
10
Input power low
Cut-Off
5000mAh
–
+
DEC
INC
INC
ON
ON
–
+
DEC
INC
INC
10.0V
Hochleistungs Profi Balance
LADER / ENTLADER
Set the results of this calculation as the number of minutes
for the safety timer setting. If the charger stops at this time
threshold, about 140% of the capacity will have been fed
into the battery.
Example:
2000 mAh 2.0 A (2000/2.0=1000)/11.9 = 84 minutes.
Capacity Cutoff Setting
8
The charging software allows the user to create a maximum
charge capacity protection setting. If the delta-peak voltage
is not properly detected or the safety timer times out, the
charge process will stop automatically when the battery
reaches the set maximum charge capacity set by the user.
Once you have established the desired settings press
„START/ENTER" to confi rm the setting then press „INC"
to move on to the next parameter.
Sound Settings (Key and Buzzer Mute)
9
A beep sounds to confi rm the every time the user presses a
button, additionally a sound is emitted during the operation
of the charger to confi rm a different mode change. These
functions can be switched on or off. Once you have established
the desired settings press „START/ENTER" to confi rm the
setting then press „INC" to move on to the next parameter.
Low Input Voltage Setting
10
This function monitors the input voltage of the DC power
source used to power the charger. If the voltage is lower
than the user setting, the program will end forcibly to protect
the input source. Once you have established the desired
settings press „START/ENTER" to confi rm the setting. You
have now set the initial user settings. You can repeat this
procedure for the other Channels.
41