Discharging Nicd Or Nimh Batteries; Charge/Discharge Cycling Of Nicd/Nimh Batteries; Charging/Discharging Lead-Acid (Pb) Batteries - Multiplex HiTEC X2-700 Multi-Charger Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Hochleistungs Profi Balance
LADER / ENTLADER

8.1. Discharging NiCd or NiMH Batteries

Set the discharge current on the left and the voltage cutoff
on the right by pressing the „START/ENTER" key for more
than 3 seconds to start the program. Discharge current can
be set from 0.1-5.0 A and voltage cutoff from 0.1-25.0 V.
This screen indicates the discharging state. You can press
the „START/ENTER" key to alter the discharge current. Press
the „START/ENTER" key again to store the setting. Press
the „BATT TYPE/STOP" key to stop discharging. The charger
will emit a sound to indicate the end of the discharge process.

8.2. Charge/Discharge Cycling of NiCd/NiMH Batteries

Set the cycle sequence on the left and the number of cycles
on the right. The battery can be cycled 1-5 times.
Press the „BATT TYPE/STOP" key to stop the program then
press the „START/ENTER" key to alter the charge or discharge
current. A sound will indicate the end of the program.
When the charger approaches the end of the program cycle,
you can view the capacity of the battery being charged or
discharged. Use the „INC" or „DEC" keys to scroll through
the results of each cycle.

9. Charging/Discharging Lead-Acid (Pb) Batteries

This program is only suitable for charging a lead-acid (PB)
type battery with a nominal voltage range of 2 to 24 volts.
Lead acid (Pb) batteries can only deliver current lower in
comparison to their capacity. The same restriction applies
to the charging process. Consequently, the optimum charge
current for lead acid (Pb) batteries is only 1/10 of its rated
capacity. You cannot fast charge lead acid (Pb) batteries.
Due to the chemistry characteristic of a Pb battery, the cut-off point may be diffi cult to detect at times.
We recommend you use the CAPACITY CUT-OFF feature to protect the battery. Refer to the Default User
Preferences Setup section of this manual to set up this feature.
46
Professional Balance Charger, Discharger
NIMH DISCHARGE
1.0A
+
DEC
INC
Batt type
stop
NiMH
1.0 A
DSC
022:45 00890
Battery
Type
Elapsed
Time
NIMH
DCHG>CHG
+
DEC
INC
Batt type
stop
NIMH 1.0A 7.42V
D>C 022:45 00890
Battery
Type
Elapsed
Discharge or
Time
Charge Current
DCHG
1
CHG
1
Please refer to the following specifi cation regarding charging
and discharging lead acid (Pb) batteries.
· Nominal Voltage Level: 2.0 V per cell
· Maximum Charge Voltage: 2.46 V per cell
· Allowable Charge Current: 0.4 C or less
· Discharge Voltage Cut Off Level: 1.75 V or higher per cell
11.5V
+
DEC
INC
Start
> 3 seconds
Enter
Battery
7.42V
Voltage
Discharged
Discharged
Capacity
Current
CYCLE
3
+
DEC
INC
Start
> 3 seconds
Enter
Battery
Voltage
Discharged or
Charged Capacity
1314mAh
1430mAh