Hochleistungs Profi Balance
LADER / ENTLADER
1.1. Warnings and Safety Information
· Have you checked the battery voltage? Lithium battery
packs can be wired in parallel and in series, i.e. a 2-cell
pack can be 3.7 V (in parallel) or 7.4 V (in series).
Standard Battery Parameters
Nominal
Voltage (V)
LiPo
3.7 V/cell
LiIon
3.6 V/cell
LiFe
3.3 V/cell
NiCd
1.2 V/cell
NiMH
1.2 V/cell
Pb
2.0 V/cell
LiHV
3.8 V/cell
Charging
During the charge process, a specifi c quantity of electrical
energy is fed into the battery. The charge quantity is
calculated by multiplying charge current by charge time.
The maximum permissible charge current varies depending
on the battery type or its performance, and can be found in
the information provided by the battery manufacturer. Only
batteries that are expressly stated to be capable of quick
charge should be charged at rates higher than the standard
charge current.
Connect the battery to the terminal of the charger. Red is
positive and black is negative. In the event there is any
signifi cant resistance in the battery cable and/or connector,
the charger will not be able to properly detect the resistance
of the battery pack resulting in an error. It is essential in
order for the charger to operate properly that the battery
charge leads should be of adequate quality for the size of
the battery.
30
Professional Balance Charger, Discharger
· Have you checked that all connections are fi rm and
secure? Make sure there are no intermittent contacts at
any point in the circuit.
Max. Charge
Storage
Voltage
Voltage
4.2 V/cell
3.8 V/cell
4.1 V/cell
3.7 V/cell
3.6 V/cell
3.3 V/cell
1.5 V/cell
n/a
1.5 V/cell
n/a
2.46 V/cell
n/a
4.35 V/cell
3.9 V/cell
Always refer to the manual by the battery manufacturer
pertaining to charging methods. Operate according to their
recommended charging current and charging time. Lithium
batteries, in particular, should be charged strictly according
to the manufacturer's instruction.
Pay close attention to the connection of lithium batteries.
Do not attempt to disassemble the battery pack.
Please take note that lithium battery packs can be wired in
parallel and in series. In the parallel connection, the battery's
capacity is calculated by multiplying the single battery's
capacity by the number of cells, bearing in mind that total
voltage stays the same. If the voltage is imbalanced, it may
cause a fi re or explosion. Lithium batteries are always
recommended to be charge in series.
Allowable
Min. Discharge
Fast Charge
Voltage
1C
3.0 V/cell
1C
2.5 V/cell
4C
2.0 V/cell
1C-2C
0.85 V/cell
1C-2C
1.0 V/cell
0.4C
1.75 V/cell
1C
3.0 V/cell