Safety During System Maintenance; Pump Identification; Technical Characteristics - Pratissoli KF Série Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
9. The high pressure system must not be started up and run
under pressure without all team members in position and
without the Operator having already directed his/her lance
toward the work area.
3.5

Safety during system maintenance

1. High pressure system maintenance must be carried out
in the time intervals set by the manufacturer who is
responsible for the whole group according to law.
2. Maintenance should always be performed by trained and
authorised personnel.
3. Assembly and disassembly of the pump and the various
components must only be carried out by authorised
personnel, using appropriate equipment in order
to prevent damage to components, in particular to
connections.
4. Always only use original spare parts to ensure total
reliability and safety.
5

TECHNICAL CHARACTERISTICS

Model
Rpm
KF 28
1000
KF 30
1000
800
1000
KF 32
KF 36
900
1000
KF 40
900
4
Each pump has its own Serial No. XX.XXX.XXX see pos.  and
an identification label, see pos.  of Fig. 1 which shows:
-
Pump model and version
-
Max revs
-
Absorbed power HP - kW
-
Pressure bar - P.S.I.
-
Flow rate l/min - Gpm
Flow rate
l/min
Gpm
92.4
24.4
106
28
122
32.2
120
31.7
137
36.2
153
40
170
45
21

PUMP IDENTIFICATION

Model, version and serial number must always be
indicated when ordering spare parts
Pressure
bar
psi
210
3045
36.8
200
2900
40.4
160
2300
180
2610
41.2
140
2050
130
1900
38.2
110
1600
Fig. 1
Power
kW
HP
50
55
37
50
56
37
50
52
36
49

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Kf 28Kf 30Kf 32Kf 36Kf 40

Table des Matières