4. The work area jet range must be absolutely prohibited to
and free from objects that, inadvertently under a pressure
jet, can be damaged and/or create dangerous situations.
5. The water jet must always and only be pointed in the
direction of the work area, including during preliminary
tests or checks.
6. The operator must always pay attention to the trajectory
of debris removed by the water jet. Where necessary,
suitable guards must be provided by the Operator to
protect anything that could become accidentally exposed.
7. The operator should not be distracted for any reason
during work. Workers needing to access the operating area
must wait for the Operator to stop work on his/her own
initiative, after which they should immediately make their
presence known.
8. It is important for safety that all team members are always
fully aware of each other's intentions in order to avoid
dangerous misunderstandings.
9. The high pressure system must not be started up and run
under pressure without all team members in position and
without the Operator having already directed his/her lance
toward the work area.
3.5

Safety during system maintenance

1. High pressure system maintenance must be carried out
in the time intervals set by the manufacturer who is
responsible for the whole group according to law.
2. Maintenance should always be performed by trained and
authorised personnel.
3. Assembly and disassembly of the pump and the various
components must only be carried out by authorized
personnel, using appropriate equipment in order
to prevent damage to components, in particular to
connections.
4. Always only use original spare parts to ensure total
reliability and safety.
5

TECHNICAL CHARACTERISTICS

Model
Rpm
800
HF 18
1000
HF 20
1000
HF 22
800
HF 22N
1000
HF 25
HF 25N
1000
HF 25N‑F
WK355
1000
4
Each pump has its own Serial No. XX.XXX.XXX see pos.  and
an identification label, see pos.  of Fig. 1 which shows:
Pump model and version
Max revs
Absorbed power HP ‑ kW
Pressure bar ‑ P.S.I.
Flow rate l/min ‑ Gpm
Flow rate
l/min
Gpm
30
8.1
38
10.1
47
12.4
45
12
57
15
73
19.3
57
15.1
23

PUMP IDENTIFICATION

Model, version and serial number must always be
indicated when ordering spare parts
Pressure
bar
psi
600
8700
35.5
500
7250
36.8
400
5800
36.8
400
5800
350
5075
280
4060
350
5075
Fig. 1
Power
kW
HP
48
50
50
35.5
48
36.8
50
36.8
50
38.1
51.8

Publicité