Plast Coat 25 · 35
• Disconnect the mortar hose from the outlet section.
• Insert cleaning ball in the mortar hose.
Re-connect the mortar hose.
• Fill water into receptacle.
When operating using the container suction system, im-
merse suction hose into receptacle with water.
Turn on mortar spraying machine.
• After a few seconds the cleaning ball will come out of the
spray lance.
• Repeat cleaning procedure 3–4 times, depending on the
coating material used.
There is a further possibility for cleaning using the cleaning
adapter.
This cleaning adapter can be connected to a water hose or
tap with a claw coupling.
Place cleaning ball in the mortar hose. Couple mortar hose to
the cleaning adapter and rinse through with water.
10.2
CLEANING DEVICE AND CHANGING PUMP
JACKET
Never remove the safety grill for any clea-
ning work!
Disassembly
• Lubricate pump.
Turn changeover switch to
Spray pump antiseize or a little dishwashing liquid into the
outlet unit (2, fig. 19) or place a little dishwashing liquid into
the receptacle and pump through the pump.
• Turn changeover switch to „0".
• Unscrew star grips (1, fig. 19).
• Remove outlet unit (2) towards the front.
• Set feed rate to „3".
• Turn changeover switch to
Danger of crushing!
• Pump jacket (3) will disconnect from pump screw.
• Set changeover switch to „0".
• Clean receptacle and receptacle lower section with a water
jet.
When operating using the container suc-
tion system, turn off device using master
switch. Remove the mains plug from the
socket and ensure that it cannot be re-
placed unintentionally.
• Unscrew and remove container connection from the recep-
• Clean receptacle lower section, container connection and
• Clean pump screw and pump jacket thoroughly with water.
• Clean outlet unit (2) inside using a bottle brush.
• Keep threads for the star grips clean and grease.
(backwards).
Pump jacket assembly
Important:
Spray pump screw and pump jacket with pump antiseize or
wet with dishwashing liquid.
• Turn changeover switch to
(forwards).
• Place pump jacket (3, fig. 19) onto pump screw. Ensure that
• Pump jacket pulls itself onto the pump screw.
• Set changeover switch to "0".
• Assemble outlet unit.
PLACING OUT OF OPERATION AND CLEANING
tacle lower section.
suction hose with a water jet and, if necessary, using a suit-
able brush.
Danger of crushing!
the ledge of the pump jacket (3) is properly slid into the rec-
tangular recess of the pump trigger (4).
2
3
4
1
(backwards).
GB