5.4. Fault: The set pressure (p refer) is not reached in the test with compressed air or compressed air pump programs.
Cause:
● Installation or compressed air hose (Fig. 4 (23)) leaking.
● No or too little pressure in the compressed air tank.
●  Electronic flushing and pressure testing unit with compressor defective.
5.5. Fault: The set pressure (p refer) is not established in the test with water program (Multi-Push SLW).
Cause:
● The water pressure of the house connection is greater than the set pressure
(p refer).
● Suction/pressure hose (Fig. 1 (13)) or high-pressure hose (Fig. 4 (26))
leaking.
● Hydro-pneumatic pump does not build up pressure.
● Stop tap of the water supply is closed or only partly open.
● No or too little air pressure in the compressed air tank.
●  Electronic flushing and pressure testing unit with compressor defective.
5.6. Fault: The pressure in the pipe to be tested is not relieved after running the test with water programs or during the test with water B, P+M.
Cause:
● Pressure relief water drain (Fig. 4 (27)) is soiled or defective.
●  Electronic flushing and pressure testing unit with compressor defective.
5.7. Fault: No or not enough ingredient is injected from the bottle.
Cause:
● Unsuitable disinfectant, cleaning, preserving agent.
● REMS V-Jet TW or REMS V-Jet H connected wrongly to the Multi-Push.
● REMS V-Jet TW or REMS V-Jet H soiled.
● REMS V-Jet TW or REMS V-Jet H defective.
●  Wrong REMS V-Jet TW or REMS V-Jet H unit connected.
5.8. Fault:  The date and time must be reset every time the electronic flushing and pressure testing unit with compressor is switched on.
Cause:
● Battery depleted.
5.9. Fault: The new version software was not installed.
Cause:
● USB stick not recognised.
● New version software is not on the USB stick.
● The USB stick was pulled out of the USB port
(Fig. 2 (33)) during the installation.
● A folder was created on the USB stick and the new version software was
copied into this folder.
5.10. Fault:  The flushing and testing programs have been incorrectly displayed on the PC.
Cause:
● The font "Lucida Console" is required for a correct display.
5.11. Fault: Printing on paper weak or illegible. Printout aborted prematurely.
Cause:
● Weak battery charge.
● Paper reel inserted incorrectly in printer.
● The printer can only be used as of Version Software 2.0.
6. Disposal
REMS Multi-Push, REMS V-Jet TW and REMS V-Jet H may not be thrown in
the household waste after use. They must be disposed of according to the legal
regulations. Take partially emptied REMS Peroxi, REMS CleanH and REMS
NoCor containers along to a collection point for special waste. Empty containers
can be disposed of with the domestic waste.
7. Manufacturer's Warranty
The warranty period shall be 12 months from delivery of the new product to the
first user. The date of delivery shall be documented by the submission of the 
original purchase documents, which must include the date of purchase and the
designation of the product. All functional defects occurring within the warranty
period, which are clearly the consequence of defects in production or materials,
will be remedied free of charge. The remedy of defects shall not extend or
renew the warranty period for the product. Damage attributable to natural wear
and tear, incorrect treatment or misuse, failure to observe the operational
instructions, unsuitable operating materials, excessive demand, use for unau-
thorized purposes, interventions by the customer or a third party or other
26
Remedy:
● Check installation for leaks. Change the compressed air hose.
● See 5.2. Fault:
●  Have the electronic flushing and pressure testing unit with compressor 
checked/repaired by an authorised REMS customer service workshop.
Remedy:
● Close the shut-off valve of the house connection.
● Change suction/pressure hose or high-pressure hose.
● Connect suction/pressure hose between the house connection and the
pressure test with water supply, see 2.6.2.
● Fully open the stop tap.
● Hydro-pneumatic pump requires compressed air, see 5.2. Fault:
●  Have the electronic flushing and pressure testing unit with compressor 
checked/repaired by an authorised REMS customer service workshop.
Remedy:
●  Clean the pressure relief water drain or have it replaced by qualified personnel 
or an authorised REMS customer service workshop.
●  Have the electronic flushing and pressure testing unit with compressor 
checked/repaired by an authorised REMS customer service workshop.
Remedy:
● Use REMS Peroxi Color, REMS CleanH, REMS NoCor.
●  Note the direction of flow arrow, see also 2.5.
● Clean REMS V-Jet TW or REMS V-Jet H, see also 4.1.
● Have REMS V-Jet TW or REMS V-Jet H checked/repaired by authorised
REMS customer service workshop.
●  Use REMS V-Jet TW exclusively for REMS Peroxi Color. 
Use REMS V-Jet H exclusively for REMS CleanH cleaner and REMS NoCor
corrosion protection.
Remedy:
● Change battery. See 4.2.
Remedy:
● Use another USB stick.
● Copy new version software to the USB stick.
● Repeat the procedure described in 2.3.. Use a USB stick with a LED if
possible.
● Move the new version software into the main directory of the USB stick.
Remedy:
● Select font "Lucida Console", install if necessary.
Remedy:
● Charge battery.
● Insert paper roll, see 3.6.
●  Load software by USB stick as a download under www.rems.de → Downloads 
→ Software into the controller of the REMS Multi-Push, see 2.3.
reasons, for which REMS is not responsible, shall be excluded from the warranty
Services under the warranty may only be provided by customer service stations
authorized for this purpose by REMS. Complaints will only be accepted if the
product is returned to a customer service station authorized by REMS without
prior interference in an unassembled condition. Replaced products and parts
shall become the property of REMS.
The user shall be responsible for the cost of shipping and returning the product.
The legal rights of the user, in particular the right to make claims against the
seller under the warranty terms, shall not be affected. This manufacturer's
warranty only applies for new products which are purchased in the European
Union, in Norway or in Switzerland.
This warranty is subject to German law with the exclusion of the United Nations
Convention on Contracts for the International Sales of Goods (CISG).
8. Spare parts lists
For spare parts lists, see www.rems.de → Downloads → Parts lists.
eng

Publicité

loading

Ce manuel est également adapté pour:

Multi-push slw