ELEC
STARTING SYSTEM
STARTER SWITCH
1. Check:
Continuity
Out of specification → Replace.
Starter continuity
(natural color coupler)
Lock plate
Position
Installed
Removed
STARTER RELAY
1. Inspect:
Brown lead terminal
Black lead terminal
Loose → Tighten.
2. Check:
Starter relay
Faulty → Replace.
Checking steps:
Connect the tester leads between the
starter relay terminals as shown.
Connect the brown lead terminal to
the positive battery terminal.
Connect the black lead terminal to the
negative battery terminal.
Check that there is continuity between
the starter relay terminals.
Check that there is no continuity after
the brown or black lead is removed.
7-19
Leads
Red
Free
Push
Free
Push
E
Brown