Position the angle on the wall
1 1
Connect the operator to the control board (VIVO-D203)
Before making any electrical connections,
check the control board instructions manual.
Before carrying out any door movement,
ensure there is no person or object in the radius
of
action
of
the
mechanisms.
Ensure the earth wire of the motors is
connected to the control board earth terminal.
door
and
the
drive
1 Mark the points (1) to drill in the pillar.
Before marking the position of the holes, ensure
the assembly positions are respected (see "Fig. 4
Assembly position for the frame and the integrated
operator").
2 Drill the points marked.
3 Position the angle (2) and secure it to the material
upon which the angle is attached, using appropriate
screws (3).
4 Attach the upper pin (1) to the angle (2) using the
pressure washers (3), screws (4) and nuts (5).
5 Position the water cover (6) using the corresponding
screws.
MAGIC built-in electromechanical operator
INSTALLATION
55