Fig.: 27. Removing the ventilator unit
Remove the ventilator unit:
f Remove the plug 2 for the power supply.
f Loosen the wing nut 1 of the ventilator unit.
f Pull the ventilator unit 3 upwards.
Fig.: 28. : Replacing the ventilator
Replace the ventilator of the ventilator unit
f Loosen the fastening nuts 3 of the ventilator 2.
f Remove the defective ventilator 3.
f Place the new ventilator 4 on the ventilator unit.
f Attach the new ventilator 4 with the fastening nuts 3.
f Reinstall the ventilator unit in reverse order.
f Connect the ventilator to the power supply.
8.3.2 Replacing the socket panel
Fig.: 29. Replacing the socket panel of the charging column
f Loosen the connected plugs on the corresponding
components.
f Loosen the fastening screws 2.
f Remove the socket panel 1.
f Install the new socket panel 1.
f Fasten the socket panel with fixing screws 2.
Tightening torque 1.8 Nm
f Connect the connected plugs to the corresponding
components.
:
1
EN
1
2
23